The SYRMEP Beamline at the ELETTRA Synchrotron (Trieste, Italy) has already been performing clinical mammographic examinations using X-rays generated by one bending magnet. These examinations have been performed with traditional screen-film systems, but in order to exploit the characteristics of the beam (monochromatic in the energy range 8.5-35 keV, with a rate up to 7 × 107 photons/(mm2·s) at 17 keV), a double layer Silicon detector has been developed within the INFN PICASSO project. This detector is the evolution of the single layer already deployed by the INFN MATISSE project, in collaboration with the Paul Scherrer Institut. This single layer was based on a microstrip Silicon sensor (50 (μm pitch) coupled to the Mythen-II high-rate photon counting ASIC, used in the edge-on configuration to improve the detection efficiency. This contribution presents the development of a double layer with limited coverage (5.5 cm instead of 21 cm), used to verify all the steps in view of the construction of the full scale assembly. We present the results in terms of rate and of the imaging capability of standard phantoms, recorded in the phase contrast imaging modality.

A DOUBLE LAYER SILICON DETECTOR FOR SINGLE PHOTON COUNTING

ARFELLI, FULVIA;CASTELLI, EDOARDO;LONGO, RENATA;RIGON, LUIGI;
2008-01-01

Abstract

The SYRMEP Beamline at the ELETTRA Synchrotron (Trieste, Italy) has already been performing clinical mammographic examinations using X-rays generated by one bending magnet. These examinations have been performed with traditional screen-film systems, but in order to exploit the characteristics of the beam (monochromatic in the energy range 8.5-35 keV, with a rate up to 7 × 107 photons/(mm2·s) at 17 keV), a double layer Silicon detector has been developed within the INFN PICASSO project. This detector is the evolution of the single layer already deployed by the INFN MATISSE project, in collaboration with the Paul Scherrer Institut. This single layer was based on a microstrip Silicon sensor (50 (μm pitch) coupled to the Mythen-II high-rate photon counting ASIC, used in the edge-on configuration to improve the detection efficiency. This contribution presents the development of a double layer with limited coverage (5.5 cm instead of 21 cm), used to verify all the steps in view of the construction of the full scale assembly. We present the results in terms of rate and of the imaging capability of standard phantoms, recorded in the phase contrast imaging modality.
2008
9789812819086
http://www.worldscientific.com/worldscibooks/10.1142/6906#t=toc
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/1908295
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact