Introduction: There are no reports on the aging effects of thermocycling of nickel-titanium (NiTi) based coil springs, and few studies have investigated their superelasticity phases in full. In this study, we compared the mechanical properties of NiTi-based closed-coil springs after the combined aging effects of prolonged strain and thermocycling, as a reflection of the clinical situation. METHODS: Ninety NiTi-based closed-coil springs were used, 30 each of the following types: (1) Nitinol (3M Unitek, Monrovia, Calif), (2) Ni-Ti (Ormco, Glendora, Calif), and (3) RMO (Rocky Mountain Orthodontics, Denver, Colo); all had similar dimensions (length, 12 mm). In each sample group, 2 equal subgroups of 15 coil springs were extended by either 50% (to 18 mm) or 150% (to 30 mm), immersed in artificial saliva, and kept at 37°C for 45 days. All springs underwent sessions of 1000 thermocycles (1 minute long) from 5°C to 55°C on days 22 and 45. Unload deflection curves from both the 50% and 150% ext

Combined aging effects of strain and thermocycling on unload deflection modes of nickel-titanium closed-coil springs. An in-vitro comparative study.

VIDONI, GABRIELE;PERINETTI, GIUSEPPE;CASTALDO, ATTILIO;CONTARDO, LUCA
2010-01-01

Abstract

Introduction: There are no reports on the aging effects of thermocycling of nickel-titanium (NiTi) based coil springs, and few studies have investigated their superelasticity phases in full. In this study, we compared the mechanical properties of NiTi-based closed-coil springs after the combined aging effects of prolonged strain and thermocycling, as a reflection of the clinical situation. METHODS: Ninety NiTi-based closed-coil springs were used, 30 each of the following types: (1) Nitinol (3M Unitek, Monrovia, Calif), (2) Ni-Ti (Ormco, Glendora, Calif), and (3) RMO (Rocky Mountain Orthodontics, Denver, Colo); all had similar dimensions (length, 12 mm). In each sample group, 2 equal subgroups of 15 coil springs were extended by either 50% (to 18 mm) or 150% (to 30 mm), immersed in artificial saliva, and kept at 37°C for 45 days. All springs underwent sessions of 1000 thermocycles (1 minute long) from 5°C to 55°C on days 22 and 45. Unload deflection curves from both the 50% and 150% ext
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2490940
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 7
social impact