We present an original application of competitive polymerase chain reaction (PCR) for measuring oncogene amplification in DNA from human tumors by simultaneous PCR amplification of genomic DNA with fixed amounts of an internal standard (competitor DNA). Competitors share the same sequence as the target genes but contain an additional 15- to 20-base-pair insert, which allows resolution of the amplified products after polyacrylamide gel electrophoresis and ethidium bromide staining. The gene copy number is derived from the ratio between the intensities of the bands corresponding to the amplified products. Using this procedure, we measured c-erbB-2 amplification in breast and bladder carcinomas in both fresh tumor tissues and paraffin-embedded tissue samples and assessed the precision, sensitivity, and accuracy of the assay. Competitive PCR is a simple, reliable, and accurate method for the evaluation of c-erbB-2 amplification and is potentially suitable for use in the clinical laboratory.

Measuring c-erbB-2 oncogene amplification in fresh and paraffin-embedded tumors by competitive polymerase chain reaction.

GIACCA, MAURO;
1994-01-01

Abstract

We present an original application of competitive polymerase chain reaction (PCR) for measuring oncogene amplification in DNA from human tumors by simultaneous PCR amplification of genomic DNA with fixed amounts of an internal standard (competitor DNA). Competitors share the same sequence as the target genes but contain an additional 15- to 20-base-pair insert, which allows resolution of the amplified products after polyacrylamide gel electrophoresis and ethidium bromide staining. The gene copy number is derived from the ratio between the intensities of the bands corresponding to the amplified products. Using this procedure, we measured c-erbB-2 amplification in breast and bladder carcinomas in both fresh tumor tissues and paraffin-embedded tissue samples and assessed the precision, sensitivity, and accuracy of the assay. Competitive PCR is a simple, reliable, and accurate method for the evaluation of c-erbB-2 amplification and is potentially suitable for use in the clinical laboratory.
1994
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2552463
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 36
  • ???jsp.display-item.citation.isi??? ND
social impact