Recently, several efforts have been devoted to the improvement of the thermal efficiency of small gas turbines, in order to approach the typical values of the internal combustion engines in the same range of power. One possibility is represented by a combined cycle, obtained coupling the gas turbine to a bottoming organic Rankine cycle (ORC). This paper deals with the definition of the main features of an ORC system aimed to recover heat from a 100 kWe commercial gas turbine with internal recuperator. After the optimization of the thermodynamic cycles, involving a comparison between six working fluids, different expanders are analyzed, with the aim of detecting, if possible, the best suited machine. First, single stage turbines, in both radial and axial flow configuration, are designed specifically for each considered fluid, in particular investigating the opportunity of mounting the ORC expander directly on the high-speed shaft of the gas turbine. Then, the performances of these dynamic machines are compared with those of positive displacement expanders, such as scroll devices, obtainable from commercial HVAC compressor with minor revisions, and reciprocating ones, here newly designed.

Bottoming organic Rankine cycle for a small scale gas turbine: a comparison of different solutions

CLEMENTE, STEFANO;MICHELI, DIEGO;REINI, MAURO;TACCANI, RODOLFO
2013-01-01

Abstract

Recently, several efforts have been devoted to the improvement of the thermal efficiency of small gas turbines, in order to approach the typical values of the internal combustion engines in the same range of power. One possibility is represented by a combined cycle, obtained coupling the gas turbine to a bottoming organic Rankine cycle (ORC). This paper deals with the definition of the main features of an ORC system aimed to recover heat from a 100 kWe commercial gas turbine with internal recuperator. After the optimization of the thermodynamic cycles, involving a comparison between six working fluids, different expanders are analyzed, with the aim of detecting, if possible, the best suited machine. First, single stage turbines, in both radial and axial flow configuration, are designed specifically for each considered fluid, in particular investigating the opportunity of mounting the ORC expander directly on the high-speed shaft of the gas turbine. Then, the performances of these dynamic machines are compared with those of positive displacement expanders, such as scroll devices, obtainable from commercial HVAC compressor with minor revisions, and reciprocating ones, here newly designed.
2013
http://dx.doi.org/10.1016/j.apenergy.2013.02.004
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2659913
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 91
  • ???jsp.display-item.citation.isi??? 79
social impact