PURPOSE: To compare image quality, radiation dose, and their relationship with heart rate of computed tomographic (CT) coronary angiographic scan protocols by using a 128-section dual-source CT scanner. MATERIALS AND METHODS: Institutional review board approved the study; all patients gave informed consent. Two hundred seventy-two patients (175 men, 97 women; mean ages, 58 and 59 years, respectively) referred for CT coronary angiography were categorized according to heart rate: less than 65 beats per minute (group A) and 65 beats per minute or greater (group B). Patients were randomized to undergo prospective high-pitch spiral scanning and narrow-window prospective sequential scanning in group A (n = 160) or wide-window prospective sequential scanning and retrospective spiral scanning in group B (n = 112). Image quality was graded (1 = nondiagnostic; 2 = artifacts present, diagnostic; 3 = no artifacts) and compared (Mann-Whitney and Student t tests). RESULTS: In group A, mean image quality grade was significantly lower with high-pitch spiral versus sequential scanning (2.67 ± 0.38 [standard deviation] vs 2.86 ± 0.21; P < .001). In a subpopulation (heart rate, <55 beats per minute), mean image quality grade was similar (2.81 ± 0.30 vs 2.94 ± 0.08; P = .35). In group B, image quality grade was comparable between sequential and retrospective spiral scanning (2.81 ± 0.28 vs 2.80 ± 0.38; P = .54). Mean estimated radiation dose was significantly lower (high-pitch spiral vs sequential scanning) in group A (for 100 kV, 0.81 mSv ± 0.30 vs 2.74 mSv ± 1.14 [P < .001]; for 120 kV, 1.65 mSv ± 0.69 vs 4.21 mSv ± 1.20 [P < .001]) and in group B (sequential vs retrospective spiral scanning) (for 100 kV, 4.07 mSv ± 1.07 vs 5.54 mSv ± 1.76 [P = .02]; for 120 kV, 7.50 mSv ± 1.79 vs 9.83 mSv ± 3.49 [P = .1]). CONCLUSION: A high-pitch spiral CT coronary angiographic protocol should be applied in patients with regular and low (<55 beats per minute) heart rates; a sequential protocol is preferred in all others.

Image quality and radiation exposure using different low-dose scan protocols in dual-source CT coronary angiography: randomized study.

ROSSI, ALEXIA;
2011-01-01

Abstract

PURPOSE: To compare image quality, radiation dose, and their relationship with heart rate of computed tomographic (CT) coronary angiographic scan protocols by using a 128-section dual-source CT scanner. MATERIALS AND METHODS: Institutional review board approved the study; all patients gave informed consent. Two hundred seventy-two patients (175 men, 97 women; mean ages, 58 and 59 years, respectively) referred for CT coronary angiography were categorized according to heart rate: less than 65 beats per minute (group A) and 65 beats per minute or greater (group B). Patients were randomized to undergo prospective high-pitch spiral scanning and narrow-window prospective sequential scanning in group A (n = 160) or wide-window prospective sequential scanning and retrospective spiral scanning in group B (n = 112). Image quality was graded (1 = nondiagnostic; 2 = artifacts present, diagnostic; 3 = no artifacts) and compared (Mann-Whitney and Student t tests). RESULTS: In group A, mean image quality grade was significantly lower with high-pitch spiral versus sequential scanning (2.67 ± 0.38 [standard deviation] vs 2.86 ± 0.21; P < .001). In a subpopulation (heart rate, <55 beats per minute), mean image quality grade was similar (2.81 ± 0.30 vs 2.94 ± 0.08; P = .35). In group B, image quality grade was comparable between sequential and retrospective spiral scanning (2.81 ± 0.28 vs 2.80 ± 0.38; P = .54). Mean estimated radiation dose was significantly lower (high-pitch spiral vs sequential scanning) in group A (for 100 kV, 0.81 mSv ± 0.30 vs 2.74 mSv ± 1.14 [P < .001]; for 120 kV, 1.65 mSv ± 0.69 vs 4.21 mSv ± 1.20 [P < .001]) and in group B (sequential vs retrospective spiral scanning) (for 100 kV, 4.07 mSv ± 1.07 vs 5.54 mSv ± 1.76 [P = .02]; for 120 kV, 7.50 mSv ± 1.79 vs 9.83 mSv ± 3.49 [P = .1]). CONCLUSION: A high-pitch spiral CT coronary angiographic protocol should be applied in patients with regular and low (<55 beats per minute) heart rates; a sequential protocol is preferred in all others.
2011
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2762009
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 68
  • ???jsp.display-item.citation.isi??? 59
social impact