Blockhaus structural systems are obtained by assembling multiple timber logs able to interact with each other by means of simple mechanisms (e.g. contacts, tongues and grooves, and carpentry joints, also referred to as 'corner' joints). Although these systems have ancient origins, the structural behaviour of Blockhaus systems under well-defined loading and boundary conditions is still complex to predict. The paper focuses on the assessment of the typical buckling behaviour and resistance of in-plane compressed timber log-walls. The effects of various mechanical and geometrical aspects such as in-plane rigid inter-storey floors, load eccentricities, different types of lateral restraints, openings (e.g. doors or windows) or additional metal stiffeners, are investigated by means of full-scale buckling experiments. Results are then critically discussed and preliminarily assessed via analytical formulations taken from classical theory of plate buckling and column buckling. Although further advanced studies are required for the development of a generalized buckling design method, it is shown that several mechanical and geometrical aspects should be properly taken into account to correctly predict the structural capacity of Blockhaus systems under in-plane compression.

Assessment of the structural stability of Blockhaus timber log-walls under in-plane compression via full-scale buckling experiments

BEDON, CHIARA;RINALDIN, GIOVANNI;IZZI, MATTEO;AMADIO, CLAUDIO
2015-01-01

Abstract

Blockhaus structural systems are obtained by assembling multiple timber logs able to interact with each other by means of simple mechanisms (e.g. contacts, tongues and grooves, and carpentry joints, also referred to as 'corner' joints). Although these systems have ancient origins, the structural behaviour of Blockhaus systems under well-defined loading and boundary conditions is still complex to predict. The paper focuses on the assessment of the typical buckling behaviour and resistance of in-plane compressed timber log-walls. The effects of various mechanical and geometrical aspects such as in-plane rigid inter-storey floors, load eccentricities, different types of lateral restraints, openings (e.g. doors or windows) or additional metal stiffeners, are investigated by means of full-scale buckling experiments. Results are then critically discussed and preliminarily assessed via analytical formulations taken from classical theory of plate buckling and column buckling. Although further advanced studies are required for the development of a generalized buckling design method, it is shown that several mechanical and geometrical aspects should be properly taken into account to correctly predict the structural capacity of Blockhaus systems under in-plane compression.
2015
http://www.sciencedirect.com/science/article/pii/S0950061815000690
File in questo prodotto:
File Dimensione Formato  
Assessment of the structural stability of Blockhaus.pdf

Accesso chiuso

Descrizione: pdf editoriale
Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 5.34 MB
Formato Adobe PDF
5.34 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
CBM_blockhaus.pdf

Open Access dal 17/05/2017

Tipologia: Bozza finale post-referaggio (post-print)
Licenza: Creative commons
Dimensione 2.89 MB
Formato Adobe PDF
2.89 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2831613
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 18
social impact