Introduction Anatomic acetabular cup, studied in 1999 by Prof. M. D’Imporzano, is born to solve the problem of acetabular revision in grade I and II mobilization (GIR), respectively, characterized by widening and deformation of cavity with eventual superior or posterior wall loss. The problem in these lesions is not such bone stock reconstruction, as correct positioning of new cup. Indeed superior wall loss can set wrong collocation of the cup tending to verticalization and superior migration of rotation centre, while posterior loss can lead to retroversion. Material and methods The hemispheric cup owns a cranial fin for iliac support with 4 holes for stabilization with spongiosa screws. In its equatorial area features 3 holes for posterior and medial screws, according to Pauwels, and circular retention cavities in order to increase the initial stability. The external shell is covered with a porous titanium layer so as to facilitate secondary osteointegration The tapered liner is in ceramic or polyethylene eventually protruded. The originality of this cup consists in having the insertion seat of the articular liner oriented by 18° in antiversion. This choice was made in order to automatically guarantee the necessary antiversion, even if the supero-posterior iliac wall is eroded, the latter being the reason why normal symmetrical revision cups lead to undesired positioning in insufficient antiversion. Considering these features, the cup can be used, as well as in revision surgery, in treatment of Coxa Profunda, Displasic Coxo-femural Osteoarthritis and acetabular fractures out-comes. In this study we present the results of 60 revisions between 2000 and 2007, with a 1–7 years follow-up. Results and conclusions The clinical outcome was good with an improvement from 55 to 88 considering the Harris Hip Score. As complications we observed only 1 case of sepsis, neither dislocation nor mobilization. Radiographical study of rotation centre pointed out a reduction of the superior migration from 1.2 to 0.8 cm after surgery. The shortness of follow-up period does not allow to conclude definitively about the effectiveness of this cup as the optimal solution in this surgery; however, we can state that it can be a valid solution for treatment of grade I and II contrasting the two principal problems of these revisions: superior migration of rotation centre and retroversion tendency.

Early results with the Revitan modular revision stem

MURENA, LUIGI;
2009-01-01

Abstract

Introduction Anatomic acetabular cup, studied in 1999 by Prof. M. D’Imporzano, is born to solve the problem of acetabular revision in grade I and II mobilization (GIR), respectively, characterized by widening and deformation of cavity with eventual superior or posterior wall loss. The problem in these lesions is not such bone stock reconstruction, as correct positioning of new cup. Indeed superior wall loss can set wrong collocation of the cup tending to verticalization and superior migration of rotation centre, while posterior loss can lead to retroversion. Material and methods The hemispheric cup owns a cranial fin for iliac support with 4 holes for stabilization with spongiosa screws. In its equatorial area features 3 holes for posterior and medial screws, according to Pauwels, and circular retention cavities in order to increase the initial stability. The external shell is covered with a porous titanium layer so as to facilitate secondary osteointegration The tapered liner is in ceramic or polyethylene eventually protruded. The originality of this cup consists in having the insertion seat of the articular liner oriented by 18° in antiversion. This choice was made in order to automatically guarantee the necessary antiversion, even if the supero-posterior iliac wall is eroded, the latter being the reason why normal symmetrical revision cups lead to undesired positioning in insufficient antiversion. Considering these features, the cup can be used, as well as in revision surgery, in treatment of Coxa Profunda, Displasic Coxo-femural Osteoarthritis and acetabular fractures out-comes. In this study we present the results of 60 revisions between 2000 and 2007, with a 1–7 years follow-up. Results and conclusions The clinical outcome was good with an improvement from 55 to 88 considering the Harris Hip Score. As complications we observed only 1 case of sepsis, neither dislocation nor mobilization. Radiographical study of rotation centre pointed out a reduction of the superior migration from 1.2 to 0.8 cm after surgery. The shortness of follow-up period does not allow to conclude definitively about the effectiveness of this cup as the optimal solution in this surgery; however, we can state that it can be a valid solution for treatment of grade I and II contrasting the two principal problems of these revisions: superior migration of rotation centre and retroversion tendency.
2009
http://link.springer.com/article/10.1007/s10195-009-0063-5
File in questo prodotto:
File Dimensione Formato  
art%3A10.1007%2Fs10195-009-0063.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 77.44 kB
Formato Adobe PDF
77.44 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2833153
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact