The aim of this study was to assess the prevalence of intraoperative complications during maxillary sinus elevation with lateral approach using a piezoelectric device with two different surgical techniques. MATERIALS AND METHODS: Antrostomies were randomly performed by outlining a window (group A, 36 patients) or by eroding the cortical wall with a grinding insert until the membrane was visible under a thin layer of bone, before outlining the window (group B, 36 patients). Occurrence of membrane perforation, laceration of vascular branches, and surgical time was recorded. RESULTS: Seventy-two patients underwent sinus floor elevation: four perforations (11.1%) were observed in group A (two occurred during elevation with hand instruments) and zero perforations in group B (p < .05). No evidence of vascular lacerations was registered in both groups. A clinically insignificant but statistically shorter surgical time was recorded in group A (9.2 ± 3.7 minutes) than in group B (13.3 ± 2.4 minutes; p < .05). CONCLUSIONS: Within the limits of the present study, it may be concluded that ultrasonic erosion of the lateral wall of the sinus is a more predictable technique than piezoelectric outlining of a bone window in preventing from accidental perforations of Schneiderian membrane during sinus augmentation procedures

Intraoperative Complications during Sinus Floor Elevation Using Two Different Ultrasonic Approaches: A Two-Center, Randomized, Controlled Clinical Trial

STACCHI, CLAUDIO
;
DI LENARDA, Roberto
2015-01-01

Abstract

The aim of this study was to assess the prevalence of intraoperative complications during maxillary sinus elevation with lateral approach using a piezoelectric device with two different surgical techniques. MATERIALS AND METHODS: Antrostomies were randomly performed by outlining a window (group A, 36 patients) or by eroding the cortical wall with a grinding insert until the membrane was visible under a thin layer of bone, before outlining the window (group B, 36 patients). Occurrence of membrane perforation, laceration of vascular branches, and surgical time was recorded. RESULTS: Seventy-two patients underwent sinus floor elevation: four perforations (11.1%) were observed in group A (two occurred during elevation with hand instruments) and zero perforations in group B (p < .05). No evidence of vascular lacerations was registered in both groups. A clinically insignificant but statistically shorter surgical time was recorded in group A (9.2 ± 3.7 minutes) than in group B (13.3 ± 2.4 minutes; p < .05). CONCLUSIONS: Within the limits of the present study, it may be concluded that ultrasonic erosion of the lateral wall of the sinus is a more predictable technique than piezoelectric outlining of a bone window in preventing from accidental perforations of Schneiderian membrane during sinus augmentation procedures
2015
22-ago-2013
Pubblicato
https://onlinelibrary.wiley.com/doi/full/10.1111/cid.12136
File in questo prodotto:
File Dimensione Formato  
Stacchi_2015_ClinImplantDentRelRes.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Copyright Editore
Dimensione 567.89 kB
Formato Adobe PDF
567.89 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
2834983_Stacchi_2015_ClinImplantDentRelRes-PostPrint.pdf

Open Access dal 23/08/2014

Descrizione: Post Print VQR3 This is the peer reviewed version of the following article: Stacchi C. et al. Intraoperative Complications during Sinus Floor Elevation Using Two Different Ultrasonic Approaches: A Two-Center, Randomized, Controlled Clinical Trial. Clin Implant Dent Relat Res. 2015 Jan;17 Suppl 1:e117-25, which has been published in final form at https://doi.org/10.1111/cid.12136. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.
Tipologia: Bozza finale post-referaggio (post-print)
Licenza: Digital Rights Management non definito
Dimensione 1.14 MB
Formato Adobe PDF
1.14 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2834983
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 40
social impact