OBJECTIVES: Annuloplasty bands and rings are widely used to treat functional tricuspid regurgitation (TR). However, the question as to which is the ideal annuloplasty device remains open. Early and late outcomes of tricuspid valve annuloplasty with flexible band (B-TVA) or rigid ring (R-TVA) are compared in the present study. METHODS: Between 1999 and 2014, 462 consecutive patients (mean age, 69.2 ± 9.5 years) with grade ≥1+ functional TR (graded from 0 to 3+) underwent either B-TVA (n = 345; mean EuroSCORE II 9.2 ± 10.8%) or R-TVA (n = 117; mean EuroSCORE II 12 ± 13.4%) in addition to other cardiac procedures at the authors' institution. RESULTS: One-to-one propensity score-matched analysis resulted in 98 pairs with similar baseline characteristics and operative risk. Hospital mortality was 7.5% after B-TVA and 12% after R-TVA (P = 0.14). R-TVA was associated with higher rates of low cardiac output (10.1 vs 17.9%, P = 0.025) and transient complete atrioventricular block (10.3 vs 17.2%, P = 0.046). Among the matched pairs, there were no significant differences in hospital mortality (5.1 vs 9.2%, P = 0.27) and perioperative complications. Both in overall series and matched pairs, between B-TVA and R-TVA patients, there were no significant differences in freedom from all-cause death (P = 0.29 and 0.91), cardiac and cerebrovascular deaths (P = 0.63 and 0.87) and grade ≥2+ TR (P = 0.68 and 0.77). Right atrial and tricuspid valve reverse remodelling combined with right ventricular reverse remodelling occurred after R-TVA but not after B-TVA. CONCLUSIONS: B-TVA and R-TVA are equally effective in the treatment of functional TR. However, R-TVA causes over time a more complete right heart reverse remodelling.

Flexible band versus rigid ring annuloplasty for functional tricuspid regurgitation: Two different patterns of right heart reverse remodelling

GATTI, GIUSEPPE;DELL'ANGELA, LUCA;MOROSIN, MARCO;MASCHIETTO, LUCA;PINAMONTI, BRUNO;BENUSSI, BERNARDO;FORTI, GABRIELLA;NICOLOSI, GIAN LUIGI;SINAGRA, GIANFRANCO;PAPPALARDO, ANIELLO
2016-01-01

Abstract

OBJECTIVES: Annuloplasty bands and rings are widely used to treat functional tricuspid regurgitation (TR). However, the question as to which is the ideal annuloplasty device remains open. Early and late outcomes of tricuspid valve annuloplasty with flexible band (B-TVA) or rigid ring (R-TVA) are compared in the present study. METHODS: Between 1999 and 2014, 462 consecutive patients (mean age, 69.2 ± 9.5 years) with grade ≥1+ functional TR (graded from 0 to 3+) underwent either B-TVA (n = 345; mean EuroSCORE II 9.2 ± 10.8%) or R-TVA (n = 117; mean EuroSCORE II 12 ± 13.4%) in addition to other cardiac procedures at the authors' institution. RESULTS: One-to-one propensity score-matched analysis resulted in 98 pairs with similar baseline characteristics and operative risk. Hospital mortality was 7.5% after B-TVA and 12% after R-TVA (P = 0.14). R-TVA was associated with higher rates of low cardiac output (10.1 vs 17.9%, P = 0.025) and transient complete atrioventricular block (10.3 vs 17.2%, P = 0.046). Among the matched pairs, there were no significant differences in hospital mortality (5.1 vs 9.2%, P = 0.27) and perioperative complications. Both in overall series and matched pairs, between B-TVA and R-TVA patients, there were no significant differences in freedom from all-cause death (P = 0.29 and 0.91), cardiac and cerebrovascular deaths (P = 0.63 and 0.87) and grade ≥2+ TR (P = 0.68 and 0.77). Right atrial and tricuspid valve reverse remodelling combined with right ventricular reverse remodelling occurred after R-TVA but not after B-TVA. CONCLUSIONS: B-TVA and R-TVA are equally effective in the treatment of functional TR. However, R-TVA causes over time a more complete right heart reverse remodelling.
2016
Pubblicato
http://icvts.oxfordjournals.org/content/23/1/79
File in questo prodotto:
File Dimensione Formato  
79.full.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 579.16 kB
Formato Adobe PDF
579.16 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
ivw047supp.pdf

Accesso chiuso

Tipologia: Altro materiale allegato
Licenza: Digital Rights Management non definito
Dimensione 178.1 kB
Formato Adobe PDF
178.1 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2878323
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 22
social impact