We determined whether the combination of low dose partial liquid ventilation (PLV) with perfluorocarbons (PFC) and prone positioning improved lung function while inducing minimal stress. Eighteen pigs with acute lung injury were assigned to conventional mechanical ventilation (CMV) or PLV (5 or 10 ml/kg of PFC). Positive end-expiratory pressure (PEEP) trials in supine and prone positions were performed. Data were analyzed by a multivariate polynomial regression model. The interplay between PLV and position depended on the PEEP level. In supine PLV dampened the stress induced by increased PEEP during the trial. The PFC dose of 5 ml/kg was more effective than the dose 10 ml/kg. This effect was not observed in prone. Oxygenation was significantly higher in prone than in supine position mainly at lower levels of PEEP. In conclusion, MV settings should take both gas exchange and stress/strain into account. When protective CMV fails, rescue strategies combining prone positioning and PLV with optimal PEEP should improve gas exchange with minimal stress. (C) 2015 Elsevier B.V. All rights reserved.

Effects on lung stress of position and different doses of perfluorocarbon in a model of ARDS

LUCANGELO, UMBERTO;
2015-01-01

Abstract

We determined whether the combination of low dose partial liquid ventilation (PLV) with perfluorocarbons (PFC) and prone positioning improved lung function while inducing minimal stress. Eighteen pigs with acute lung injury were assigned to conventional mechanical ventilation (CMV) or PLV (5 or 10 ml/kg of PFC). Positive end-expiratory pressure (PEEP) trials in supine and prone positions were performed. Data were analyzed by a multivariate polynomial regression model. The interplay between PLV and position depended on the PEEP level. In supine PLV dampened the stress induced by increased PEEP during the trial. The PFC dose of 5 ml/kg was more effective than the dose 10 ml/kg. This effect was not observed in prone. Oxygenation was significantly higher in prone than in supine position mainly at lower levels of PEEP. In conclusion, MV settings should take both gas exchange and stress/strain into account. When protective CMV fails, rescue strategies combining prone positioning and PLV with optimal PEEP should improve gas exchange with minimal stress. (C) 2015 Elsevier B.V. All rights reserved.
2015
http://www.sciencedirect.com/science/journal/15699048
File in questo prodotto:
File Dimensione Formato  
Effects on lung stress of position and different doses of perfluorocarbon in a model of ARDS.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 1.53 MB
Formato Adobe PDF
1.53 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2892234
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact