Glazing facades are widely used in building structures, due to a series of aesthetic, thermal, lightening aspects. From a structural point of view, under the action of exceptional loads as impacts, explosions, seismic events or hazards in general, the glazing envelopes often represent the critical component for multi-storey buildings, due to the typically brittle behaviour and limited tensile resistance of the glass panes, hence requiring specific, fail-safe design concepts. In this paper, the feasibility and potential of special mechanical connectors interposed at the interface between a given multi-storey primary building structure and the glazing facade are investigated via accurate finite-element numerical models, under various impact scenarios. As shown, the final result is an assembled structural system in which the facade can work as passive control system for the primary structure, in the form of a distributed tuned-mass damper (TMD).
Improving the dynamic performance of multi-storey buildings via protective glazing curtain walls
Bedon, Chiara
;Amadio, Claudio
2018-01-01
Abstract
Glazing facades are widely used in building structures, due to a series of aesthetic, thermal, lightening aspects. From a structural point of view, under the action of exceptional loads as impacts, explosions, seismic events or hazards in general, the glazing envelopes often represent the critical component for multi-storey buildings, due to the typically brittle behaviour and limited tensile resistance of the glass panes, hence requiring specific, fail-safe design concepts. In this paper, the feasibility and potential of special mechanical connectors interposed at the interface between a given multi-storey primary building structure and the glazing facade are investigated via accurate finite-element numerical models, under various impact scenarios. As shown, the final result is an assembled structural system in which the facade can work as passive control system for the primary structure, in the form of a distributed tuned-mass damper (TMD).File | Dimensione | Formato | |
---|---|---|---|
WIT_book.pdf
Accesso chiuso
Tipologia:
Altro materiale allegato
Licenza:
Copyright Editore
Dimensione
353.59 kB
Formato
Adobe PDF
|
353.59 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
WIT_book-paper.pdf
Accesso chiuso
Tipologia:
Documento in Versione Editoriale
Licenza:
Copyright Editore
Dimensione
1.27 MB
Formato
Adobe PDF
|
1.27 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate