Purpose: To analyze and compare the surface properties of commercially available hydrophobic acrylic intraocular lenses (IOLs). Setting: Eye Clinic, University of Trieste, Italy. Design: Experimental study. Methods: The following 6 single-piece hydrophobic acrylic IOL models with the same dioptric power were studied and compared: Clareon SY60WF, Tecnis PCB00, enVista MX60, CT Lucia 601P, Vivinex iSert XY1, and iSert 251. Topography of the IOL surface was analyzed using atomic force microscopy (AFM). Surface contact angle measurements using the sessile drop method were performed to assess IOL wettability. Results: The AFM analysis showed that the Vivinex iSert XY1 IOL and Clareon SY60WF IOL had the lowest surface roughness (P < .05); there was no statistically significant difference in surface roughness between the those 2 IOL models (P > .05). Surface contact angle measurements showed that the iSert 251 IOL had the highest hydrophobicity. The CT Lucia 601P IOL had the lowest contact angle of all IOL models. Conclusions: The AFM analysis and surface contact angle measurements of all IOLs tested showed that the Vivinex iSert XY1 IOL and Clareon SY60WF IOL had the best topographic features. The smoother, more regular surface of these new IOL models might reduce cell adhesion and therefore lower the incidence of posterior capsule opacification.

Surface properties of commercially available hydrophobic acrylic intraocular lenses: Comparative study

Chiara De Giacinto
;
Davide Porrelli;Gianluca Turco;Marco Rocco Pastore;Rossella D'Aloisio;Daniele Tognetto
2019-01-01

Abstract

Purpose: To analyze and compare the surface properties of commercially available hydrophobic acrylic intraocular lenses (IOLs). Setting: Eye Clinic, University of Trieste, Italy. Design: Experimental study. Methods: The following 6 single-piece hydrophobic acrylic IOL models with the same dioptric power were studied and compared: Clareon SY60WF, Tecnis PCB00, enVista MX60, CT Lucia 601P, Vivinex iSert XY1, and iSert 251. Topography of the IOL surface was analyzed using atomic force microscopy (AFM). Surface contact angle measurements using the sessile drop method were performed to assess IOL wettability. Results: The AFM analysis showed that the Vivinex iSert XY1 IOL and Clareon SY60WF IOL had the lowest surface roughness (P < .05); there was no statistically significant difference in surface roughness between the those 2 IOL models (P > .05). Surface contact angle measurements showed that the iSert 251 IOL had the highest hydrophobicity. The CT Lucia 601P IOL had the lowest contact angle of all IOL models. Conclusions: The AFM analysis and surface contact angle measurements of all IOLs tested showed that the Vivinex iSert XY1 IOL and Clareon SY60WF IOL had the best topographic features. The smoother, more regular surface of these new IOL models might reduce cell adhesion and therefore lower the incidence of posterior capsule opacification.
2019
Pubblicato
https://www.sciencedirect.com/science/article/pii/S088633501930286X?via=ihub
File in questo prodotto:
File Dimensione Formato  
De Giacinto.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 2.04 MB
Formato Adobe PDF
2.04 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
2951486_De Giacinto-PostPrint.pdf

accesso aperto

Descrizione: Post Print VQR3
Tipologia: Bozza finale post-referaggio (post-print)
Licenza: Digital Rights Management non definito
Dimensione 2.63 MB
Formato Adobe PDF
2.63 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2951486
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 14
social impact