Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
ArTS Archivio della ricerca di Trieste
We have started the development of a detector system, sensitive to single photons in the eV energy range, to be suitably coupled to one of the CAST magnet ports. This system should open to CAST a window on possible detection of low energy Axion Like Particles emitted by the sun. Preliminary tests have involved a cooled photomultiplier tube coupled to the CAST magnet via a Galileian telescope and a switched 40 m long optical fiber. This system has reached the limit background level of the detector alone in ideal conditions, and two solar tracking runs have been performed with it at CAST. Such a measurement has never been done before with an axion helioscope. We will present results from these runs and briefly discuss future detector developments.
Search for low Energy solar Axions with CAST / Cantatore, G., FOR THE CAST COLLABORATION E., A., S., A., D., A., K., B., A., B., B., B., S., B., F. S., B., H., B., Cantatore, G., J. M., C., S., C., S. A., C., J. I., C., T., D., M., D., L., D.L., O. B., D., C., E., et al.. - ELETTRONICO. - (2008), pp. 43-47. (4th Patras Workshop on Axions, WIMPs and WISPs Amburgo 18-21 Giugno 2008).
Search for low Energy solar Axions with CAST
CANTATORE, GIOVANNI;FOR THE CAST COLLABORATION E. ARIK;S. AUNE;D. AUTIERO;K. BARTH;A. BELOV;B. BELTRÁN;S. BORGHI;F. S. BOYDAG;H. BRÄUNINGER;CANTATORE G.;J. M. CARMONA;S. CEBRIÁN;S. A. CETIN;J. I. COLLAR;T. DAFNI;M. DAVENPORT;L. DI LELLA;O. B. DOGAN;C. ELEFTHERIADIS;N. ELIAS;G. FANOURAKIS;E. FERRER RIBAS;H. FISCHER;J. FRANZ;J. GALÁN;E. GAZIS;T. GERALIS;I. GIOMATARIS;S. GNINENKO;H. GÓMEZ;M. HASINOFF;F. H. HEINSIUS;I. HIKMET;D. H. H. HOFFMANN;I. G. IRASTORZA;J. JACOBY;K. JAKOVÄIÄ;D. KANG;T. KARAGEORGOPOULOU;M. KARUZA;K. KÖNIGSMANN;R. KOTTHAUS;M. KRÄMAR;K. KOUSOURIS;M. KUSTER;B. LAKIÄ;C. LASSEUR;A. LIOLIOS;A. LJUBIÄIÄ;V. LOZZA;G. LUTZ;G. LUZÓN;D. MILLER;A. MORALES;DECEASED;J. MORALES;T. NIINIKOSKI;A. NORDT;A. ORTIZ;T. PAPAEVANGELOU;M. PIVOVAROFF;A. PLACCI;G. RAITERI;G. RAFFELT;H. RIEGE;A. RODRÍGUEZ;J. RUZ;I. SAVVIDIS;Y. SEMERTZIDIS;P. SERPICO;S. K. SOLANKI;R. SOUFLI;L. STEWART;M. TSAGRI;K. VAN BIBBER;J. VILLAR;J. VOGEL;L. WALCKIERS;K. ZIOUTAS
2008-01-01
Abstract
We have started the development of a detector system, sensitive to single photons in the eV energy range, to be suitably coupled to one of the CAST magnet ports. This system should open to CAST a window on possible detection of low energy Axion Like Particles emitted by the sun. Preliminary tests have involved a cooled photomultiplier tube coupled to the CAST magnet via a Galileian telescope and a switched 40 m long optical fiber. This system has reached the limit background level of the detector alone in ideal conditions, and two solar tracking runs have been performed with it at CAST. Such a measurement has never been done before with an axion helioscope. We will present results from these runs and briefly discuss future detector developments.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/1908364
Avviso
Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.
Citazioni
ND
ND
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.