In the recent years, an increasing interest has been directed toward the exploitation of silver nanoparticle technology in the development of bioactive biomaterials as well as in food and general biomedical applications. The antibacterial effect and the toxicity toward eukaryotic cells seem to be related, among others, to size and shape of such nanoparticles. A quantitative characterization of their morphology allows for a better understanding of their formation and stabilization improving their efficacy and safety in the design of the nanocomposite system. To this end, an image analysis methodology is proposed in the present paper. Starting from Transmission Electron Microscopy (TEM) images of the nanoparticles and by means of proper segmentation, the proposed automated protocol can be employed as a size calculator as well as a shape descriptor. This methodology has been applied to a silver nanoparticle-polysaccharide nanocomposite system developed for biomaterials applications [1]. This study is a first step towards the development of automatic tools that are able to quantitatively analyze TEM images overcoming the subjectivity of human visual inspection.

Characterization of silver nanoparticles for biomedical applications by means of quantitative analysis of TEM micrographs

BRUN, FRANCESCO;TRAVAN, Andrea;ACCARDO, AGOSTINO;PAOLETTI, SERGIO
2010-01-01

Abstract

In the recent years, an increasing interest has been directed toward the exploitation of silver nanoparticle technology in the development of bioactive biomaterials as well as in food and general biomedical applications. The antibacterial effect and the toxicity toward eukaryotic cells seem to be related, among others, to size and shape of such nanoparticles. A quantitative characterization of their morphology allows for a better understanding of their formation and stabilization improving their efficacy and safety in the design of the nanocomposite system. To this end, an image analysis methodology is proposed in the present paper. Starting from Transmission Electron Microscopy (TEM) images of the nanoparticles and by means of proper segmentation, the proposed automated protocol can be employed as a size calculator as well as a shape descriptor. This methodology has been applied to a silver nanoparticle-polysaccharide nanocomposite system developed for biomaterials applications [1]. This study is a first step towards the development of automatic tools that are able to quantitatively analyze TEM images overcoming the subjectivity of human visual inspection.
2010
9781936007394
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2304021
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact