The Fermi@elettra cavity BPM (C-BPM) system is based on an original implementation of the C-BPM scheme as the pick-up, operating at 6.5GHz, is coupled to a dedicated, self-calibrating electronics based on a novel concept. The system has been developed in-house; both the E-M and the mechanical design of the pick-up have been carried out, including an original frequency tuning scheme. The detector electronics directly obtains the envelope of the sum and difference signals by means of an RF 180° hybrid; no mixer for the RF signal down conversion is used. The detector is based on 3 blocks: an RF front-end, a baseband analogue transmission module and a digital back-end unit, based on a micro-TCA platform. The digital back-end is equipped with a powerful Virtex 5 FPGA and several real-time tasks have been implemented on it, including intra-pulse calibration. Ten C-BPM stations have been installed so far, fully integrated in the FERMI control System, enabling a real-time control of this key FEL diagnostics. Results on performances with beam are also presented; the scale factor of C-BPMs is obtained with beam, as two-axis micrometer translation stages have been installed.

The Fermi@Elettra Cavity BPM System: Description and Commissioning Results

DAL FORNO, MASSIMO;
2011-01-01

Abstract

The Fermi@elettra cavity BPM (C-BPM) system is based on an original implementation of the C-BPM scheme as the pick-up, operating at 6.5GHz, is coupled to a dedicated, self-calibrating electronics based on a novel concept. The system has been developed in-house; both the E-M and the mechanical design of the pick-up have been carried out, including an original frequency tuning scheme. The detector electronics directly obtains the envelope of the sum and difference signals by means of an RF 180° hybrid; no mixer for the RF signal down conversion is used. The detector is based on 3 blocks: an RF front-end, a baseband analogue transmission module and a digital back-end unit, based on a micro-TCA platform. The digital back-end is equipped with a powerful Virtex 5 FPGA and several real-time tasks have been implemented on it, including intra-pulse calibration. Ten C-BPM stations have been installed so far, fully integrated in the FERMI control System, enabling a real-time control of this key FEL diagnostics. Results on performances with beam are also presented; the scale factor of C-BPMs is obtained with beam, as two-axis micrometer translation stages have been installed.
2011
9780000000002
Cavity BPM; Free Electron Laser
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2397471
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact