The availability of a fully-portable Partial Discharge (PD) instrument based of an antenna probe, is quite attractive but additional degree of freedom that is, the position of the probe and the distance from the tested object, have to be considered to optimize its use. The optimum location of the antenna probe has been investigated through both laboratory and on-site experiments carried out on coils, stator windings and complete rotating machines. Both calibrated pulse signals and PD patterns were recorded at different distances and positions along the tested object and the results were compared with those obtained using a PD instrument connected with a coupling capacitor and a current transformer. It was found that the diagnostic information remains almost the same when the sensor is moved along the tested object and it is comparable with that obtained using the different sensors. It was also found that the surface discharges can be located with accuracy and the internal discharges are more evident when the antenna is positioned in correspondence of conductive’ discontinuities e.g., the edge of the slot-stress grading in the radiating near-field region.

PD Detection in Rotating Machines Using a Portable Instrument Based on an Antenna Probe

A. Contin
Writing – Original Draft Preparation
;
2017-01-01

Abstract

The availability of a fully-portable Partial Discharge (PD) instrument based of an antenna probe, is quite attractive but additional degree of freedom that is, the position of the probe and the distance from the tested object, have to be considered to optimize its use. The optimum location of the antenna probe has been investigated through both laboratory and on-site experiments carried out on coils, stator windings and complete rotating machines. Both calibrated pulse signals and PD patterns were recorded at different distances and positions along the tested object and the results were compared with those obtained using a PD instrument connected with a coupling capacitor and a current transformer. It was found that the diagnostic information remains almost the same when the sensor is moved along the tested object and it is comparable with that obtained using the different sensors. It was also found that the surface discharges can be located with accuracy and the internal discharges are more evident when the antenna is positioned in correspondence of conductive’ discontinuities e.g., the edge of the slot-stress grading in the radiating near-field region.
File in questo prodotto:
File Dimensione Formato  
EIC conference Contin.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Copyright Editore
Dimensione 476.17 kB
Formato Adobe PDF
476.17 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2921479
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact