Scanning transmission x-ray microscopy (STXM) and coherent diffractive imaging (CDI) are imaging techniques that have evolved quite separately. STXM features straightforward data analysis but its resolution is limited by the spot size on the specimen. As for CDI, its promises to reach resolutions below 10 nm are often hindered by many stringent requirements on the quality of the collected datasets and on the characteristics of the specimen. We describe a ptychographic imaging method that addresses these challenges by bridging the gap between CDI and STXM through the collection of coherent diffraction patterns at each point of a STXM scan. We demonstrate this approach in a hard X-ray experiment, obtaining a five-fold improvement in resolution compared to the focal spot dimensions. The reconstruction algorithm extracts from the data not only the complex-valued transmission function of the specimen but also the complete structure of the wavefield incident on it. The method is expected to allow high-resolution imaging of a wide range of materials and life science specimens. © EDP Sciences, 2009.

High-resolution scanning coherent X-ray diffraction microscopy

P. Thibault;
2009-01-01

Abstract

Scanning transmission x-ray microscopy (STXM) and coherent diffractive imaging (CDI) are imaging techniques that have evolved quite separately. STXM features straightforward data analysis but its resolution is limited by the spot size on the specimen. As for CDI, its promises to reach resolutions below 10 nm are often hindered by many stringent requirements on the quality of the collected datasets and on the characteristics of the specimen. We describe a ptychographic imaging method that addresses these challenges by bridging the gap between CDI and STXM through the collection of coherent diffraction patterns at each point of a STXM scan. We demonstrate this approach in a hard X-ray experiment, obtaining a five-fold improvement in resolution compared to the focal spot dimensions. The reconstruction algorithm extracts from the data not only the complex-valued transmission function of the specimen but also the complete structure of the wavefield incident on it. The method is expected to allow high-resolution imaging of a wide range of materials and life science specimens. © EDP Sciences, 2009.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2977330
 Avviso

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact