This paper (Part II), together with a companion one (Part I), deals with the fault-tolerant operation of a 5-phase permanent magnet (PM) brushless DC (BLDC) drive. In particular, this paper takes advantage of the drive model formulated in Part I to determine automatically the motor current supply, namely scheduling and magnitude of the currents for the surviving phases, in the cases of a drive with two and three open phase faults. Maximum magnitude of the supply currents is also determined by equating the rms value of current in the most solicited phase to the nominal rms value Open faults of adjacent and non-adjacent phases are studied and for each fault location, besides determining the motor current supply, the torque developed by the motor is calculated. The results indicate that the reduction in the motor torque as well as the extent of the torque ripple is depending on the relative location of the faults.

An algebraic approach to determine the current supply in a faulty 5-phase PM BLDC drive. Part II - application to the cases of two and three open phase faults

BUJA, GIUSEPPE;TESSAROLO, ALBERTO
2015-01-01

Abstract

This paper (Part II), together with a companion one (Part I), deals with the fault-tolerant operation of a 5-phase permanent magnet (PM) brushless DC (BLDC) drive. In particular, this paper takes advantage of the drive model formulated in Part I to determine automatically the motor current supply, namely scheduling and magnitude of the currents for the surviving phases, in the cases of a drive with two and three open phase faults. Maximum magnitude of the supply currents is also determined by equating the rms value of current in the most solicited phase to the nominal rms value Open faults of adjacent and non-adjacent phases are studied and for each fault location, besides determining the motor current supply, the torque developed by the motor is calculated. The results indicate that the reduction in the motor torque as well as the extent of the torque ripple is depending on the relative location of the faults.
File in questo prodotto:
File Dimensione Formato  
An Algebraic Approach to Determine the Current Supply in a Faulty 5-Phase PM BLDC Drive. Part II.pdf

Accesso chiuso

Descrizione: PDF versione editoriale
Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 2.42 MB
Formato Adobe PDF
2.42 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2869712
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 0
social impact