The use of structural glass for load-bearing composite systems in building is increasing. Typical solutions can take the form of hybrid systems in which glass interacts with steel, aluminum or timber, under a multitude of boundary and loading conditions of technical interest. Among others, fire accidents represent a critical design condition for glass and glass composites, and require dedicated performance indicators and validation methods. In this paper, the load-bearing performance of a composite timber-glass panel for load-bearing applications is explored under the effects of sustained mechanical loads (25 kN/m) and fire exposure (standard furnace test). A pilot test is carried out on a full-scale prototype of timber-glass prefabricated module, based on conventional recommendations for the experimental assessment of constructional members in fire. As shown, its overall load-bearing performance is governed by the intrinsic properties of timber (for the perimetral frame) and glass (for the insulated (IGU) panel), that is used to cover up to 3.2×2.7 square meters of facade, with a relatively small thickness (63.52 mm IGU thickness). The fire endurance is thus addressed towards reference performance indicators for vertical load-bearing members (i.e., walls) and towards the observations of the pilot experiment.

Load-bearing composite timber-glass wall prototype in fire conditions

Bedon, Chiara
Membro del Collaboration Group
;
2021-01-01

Abstract

The use of structural glass for load-bearing composite systems in building is increasing. Typical solutions can take the form of hybrid systems in which glass interacts with steel, aluminum or timber, under a multitude of boundary and loading conditions of technical interest. Among others, fire accidents represent a critical design condition for glass and glass composites, and require dedicated performance indicators and validation methods. In this paper, the load-bearing performance of a composite timber-glass panel for load-bearing applications is explored under the effects of sustained mechanical loads (25 kN/m) and fire exposure (standard furnace test). A pilot test is carried out on a full-scale prototype of timber-glass prefabricated module, based on conventional recommendations for the experimental assessment of constructional members in fire. As shown, its overall load-bearing performance is governed by the intrinsic properties of timber (for the perimetral frame) and glass (for the insulated (IGU) panel), that is used to cover up to 3.2×2.7 square meters of facade, with a relatively small thickness (63.52 mm IGU thickness). The fire endurance is thus addressed towards reference performance indicators for vertical load-bearing members (i.e., walls) and towards the observations of the pilot experiment.
2021
9789616884716
File in questo prodotto:
File Dimensione Formato  
asfe_wall.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Copyright Editore
Dimensione 1.07 MB
Formato Adobe PDF
1.07 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2992610
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact