Single-shot K-Edge Subtraction X-ray Computed Tomography (CT) with a multi-threshold photon-counting detector is an interesting approach to favour low-dose analyses of a known contrast agent with promising applications in vivo. To assess the minimum detectable concentration of the contrast agent and to favour possible radiation dose reduction and/or faster acquisition time, a significant role is played by the tomographic reconstruction algorithm. By considering experimental images, this work evaluates three CT reconstruction methods and different acquisition statistics via a no-reference assessment of contrast-to-noise ratio and spatial resolution. The results support that, although computationally expensive, a SART-TV reconstruction approach yields adequate results even when a limited number of projections is available.

No-reference evaluation of the reconstructed images in single-shot K-Edge Subtraction X-ray Computed Tomography

Saccomano G.
Investigation
;
Di Trapani V.
Methodology
;
Brun F.
Supervision
2020-01-01

Abstract

Single-shot K-Edge Subtraction X-ray Computed Tomography (CT) with a multi-threshold photon-counting detector is an interesting approach to favour low-dose analyses of a known contrast agent with promising applications in vivo. To assess the minimum detectable concentration of the contrast agent and to favour possible radiation dose reduction and/or faster acquisition time, a significant role is played by the tomographic reconstruction algorithm. By considering experimental images, this work evaluates three CT reconstruction methods and different acquisition statistics via a no-reference assessment of contrast-to-noise ratio and spatial resolution. The results support that, although computationally expensive, a SART-TV reconstruction approach yields adequate results even when a limited number of projections is available.
File in questo prodotto:
File Dimensione Formato  
Saccomano et al - No reference evaluation of the reconstructed images in single-shot K-Edge Subtraction x-ray computed tomography.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 2.06 MB
Formato Adobe PDF
2.06 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/3068679
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact