The study of the site effects and the microzonation of a part of the metropolitan Sofia, based on the modelling of seismic ground motion along three cross-sections are performed. Realistic synthetic strong motion waveforms are computed for scenario earthquakes (M 1⁄4 7) applying a hybrid modelling method, based on the modal summation technique and finite differences scheme. The synthesized ground motion time histories are source and site specific. The site amplification is determined in terms of response spectra ratio (RSR). A suite of time histories and quantities of earthquake engineering interest are provided. The results of this study constitute a ‘‘database’’ that describes the ground shaking of the urban area. A case study of experiment-based assessment of vulnerability of a cast-in-situ single storey, industrial, reinforced concrete frame, designed according to Eurocodes 2 and 8 is presented. The main characteristics of damage index and storey drift are discussed for the purposes of microzonation.

An earthquake scenario for the microzonation of Sofia and the vulnerability of structures designed by use of the Eurocodes

PANZA, GIULIANO;VACCARI, FRANCO
2007-01-01

Abstract

The study of the site effects and the microzonation of a part of the metropolitan Sofia, based on the modelling of seismic ground motion along three cross-sections are performed. Realistic synthetic strong motion waveforms are computed for scenario earthquakes (M 1⁄4 7) applying a hybrid modelling method, based on the modal summation technique and finite differences scheme. The synthesized ground motion time histories are source and site specific. The site amplification is determined in terms of response spectra ratio (RSR). A suite of time histories and quantities of earthquake engineering interest are provided. The results of this study constitute a ‘‘database’’ that describes the ground shaking of the urban area. A case study of experiment-based assessment of vulnerability of a cast-in-situ single storey, industrial, reinforced concrete frame, designed according to Eurocodes 2 and 8 is presented. The main characteristics of damage index and storey drift are discussed for the purposes of microzonation.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/1698618
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? ND
social impact