PURPOSE: To evaluate the diagnostic accuracy of 16-row multislice spiral computed tomography coronary angiography (16-MSCT-CA) for the non-invasive assessment of significant coronary artery stenosis. MATERIALS AND METHODS: We enrolled 40 patients (36 male, aged 59+/-11 yrs) with suspected obstructive coronary artery disease and a heart rate <65 bpm during the scan. The 16-MSCT-CA (Sensation 16, Siemens, Forchheim, Germany) was performed with electrocardiographically-gated technique after the intravenous administration of 100 ml of iodinated contrast material followed by a saline bolus chaser. The scan parameters were: collimation 16 x 0.75 mm, rotation time 0.42 s, feed/rot. 3 mm (pitch 0.25), 120 kVp, 500 mAs. All coronary segments = or >2 mm in diameter were evaluated by two independent observers for the presence of significant coronary artery stenosis (= or >50%). Consensus reading was compared to quantitative coronary angiography. RESULTS: The average heart rate was 55+/-6 bpm. Of the 428 segments of = or >2.0 mm diameter 92 were significantly diseased. Without exclusion of any branches (428), the sensitivity, specificity, positive, and negative predictive values to identify = or >50% obstructed segments were 95.7% (88/92), 95.8% (322/336), 86.3% (88/102), and 98.8% (322/326), respectively. No occluded left main, left anterior descending, circumflex or right coronary artery segments remained undetected. CONCLUSIONS: 16-MSCT-CA in a selected low-heart-rate patient population provides high diagnostic accuracy in the evaluation of significant coronary artery stenosis.

Diagnostic accuracy of 16-row multislice CT angiography in the evaluation of coronary segments

BELGRANO, MANUEL GIANVALERIO
2005-01-01

Abstract

PURPOSE: To evaluate the diagnostic accuracy of 16-row multislice spiral computed tomography coronary angiography (16-MSCT-CA) for the non-invasive assessment of significant coronary artery stenosis. MATERIALS AND METHODS: We enrolled 40 patients (36 male, aged 59+/-11 yrs) with suspected obstructive coronary artery disease and a heart rate <65 bpm during the scan. The 16-MSCT-CA (Sensation 16, Siemens, Forchheim, Germany) was performed with electrocardiographically-gated technique after the intravenous administration of 100 ml of iodinated contrast material followed by a saline bolus chaser. The scan parameters were: collimation 16 x 0.75 mm, rotation time 0.42 s, feed/rot. 3 mm (pitch 0.25), 120 kVp, 500 mAs. All coronary segments = or >2 mm in diameter were evaluated by two independent observers for the presence of significant coronary artery stenosis (= or >50%). Consensus reading was compared to quantitative coronary angiography. RESULTS: The average heart rate was 55+/-6 bpm. Of the 428 segments of = or >2.0 mm diameter 92 were significantly diseased. Without exclusion of any branches (428), the sensitivity, specificity, positive, and negative predictive values to identify = or >50% obstructed segments were 95.7% (88/92), 95.8% (322/336), 86.3% (88/102), and 98.8% (322/326), respectively. No occluded left main, left anterior descending, circumflex or right coronary artery segments remained undetected. CONCLUSIONS: 16-MSCT-CA in a selected low-heart-rate patient population provides high diagnostic accuracy in the evaluation of significant coronary artery stenosis.
2005
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2297798
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact