The effectiveness of contrast- enhanced ultrasonography (CEUS) in the evaluation of patients with acute renal infarcts was investigated, using contrast-enhanced helical computed tomography (CT) as the reference imaging procedure. Twentyseven consecutive patients with acute renal infarcts detected with contrast enhanced helical CT underwent CEUS. Digital cine-clips of CEUS were evaluated by two independent readers blinded to CT findings. Image quality was rated subjectively on a four-point scale. Then, readers were asked to assign a confidence level in diagnosis of renal infarct at the upper pole, medium portion, and lower pole of each kidney according to a five degree scale, ranging from definitely absent to definitely present. ROC curve analysis was employed to assess the overall confidence of diagnosis of infarct, and weighted kappa values were calculated to assess inter-reader agreement. The subjective image quality of CEUS was lower than the image quality of CTat the upper poles. However, the diagnostic performance of CEUS was excellent (area under receiver-operator characteristic curve 0.992±0.006 for reader 1; 0.991± 0.007 for reader 2), with very good inter-reader agreement (weighted kappa value=0.83). CEUS is a reproducible tool to detect acute renal infarcts in men, with a diagnostic performance approaching that of CT.

Value of contrast-enhanced ultrasonography for detecting renal infarcts proven by contrast enhanced CT. A feasibility study

BERTOLOTTO, MICHELE;COVA, MARIA ASSUNTA
2008-01-01

Abstract

The effectiveness of contrast- enhanced ultrasonography (CEUS) in the evaluation of patients with acute renal infarcts was investigated, using contrast-enhanced helical computed tomography (CT) as the reference imaging procedure. Twentyseven consecutive patients with acute renal infarcts detected with contrast enhanced helical CT underwent CEUS. Digital cine-clips of CEUS were evaluated by two independent readers blinded to CT findings. Image quality was rated subjectively on a four-point scale. Then, readers were asked to assign a confidence level in diagnosis of renal infarct at the upper pole, medium portion, and lower pole of each kidney according to a five degree scale, ranging from definitely absent to definitely present. ROC curve analysis was employed to assess the overall confidence of diagnosis of infarct, and weighted kappa values were calculated to assess inter-reader agreement. The subjective image quality of CEUS was lower than the image quality of CTat the upper poles. However, the diagnostic performance of CEUS was excellent (area under receiver-operator characteristic curve 0.992±0.006 for reader 1; 0.991± 0.007 for reader 2), with very good inter-reader agreement (weighted kappa value=0.83). CEUS is a reproducible tool to detect acute renal infarcts in men, with a diagnostic performance approaching that of CT.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2298400
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 64
  • ???jsp.display-item.citation.isi??? 57
social impact