We report the case of a patient that had undergone a left pneumonectomy during which a double-lumen tube was used and an undetected right bronchial laceration occurred. After diagnosis the patient underwent a second operation to repair the tear. The role of high-frequency percussive ventilation in enabling adequate gas exchange during the bronchial repair is described and discussed.
High-frequency percussive ventilation during surgical bronchial repair in a patient with one lung.
LUCANGELO, UMBERTO;
2006-01-01
Abstract
We report the case of a patient that had undergone a left pneumonectomy during which a double-lumen tube was used and an undetected right bronchial laceration occurred. After diagnosis the patient underwent a second operation to repair the tear. The role of high-frequency percussive ventilation in enabling adequate gas exchange during the bronchial repair is described and discussed.File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.