We report the case of a patient that had undergone a left pneumonectomy during which a double-lumen tube was used and an undetected right bronchial laceration occurred. After diagnosis the patient underwent a second operation to repair the tear. The role of high-frequency percussive ventilation in enabling adequate gas exchange during the bronchial repair is described and discussed.
High-frequency percussive ventilation during surgical bronchial repair in a patient with one lung / Lucangelo, Umberto; Zin, W. A.; Antonaglia, V.; Gramaticopolo, S.; Maffessanti, M.; Liguori, G.; Cortale, M.; Gullo, A.. - In: BRITISH JOURNAL OF ANAESTHESIA. - ISSN 0007-0912. - STAMPA. - 96:4(2006), pp. 533-536. [10.1093/bja/ael026]
High-frequency percussive ventilation during surgical bronchial repair in a patient with one lung.
LUCANGELO, UMBERTO;
2006-01-01
Abstract
We report the case of a patient that had undergone a left pneumonectomy during which a double-lumen tube was used and an undetected right bronchial laceration occurred. After diagnosis the patient underwent a second operation to repair the tear. The role of high-frequency percussive ventilation in enabling adequate gas exchange during the bronchial repair is described and discussed.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.