Purpose: The purpose of this study was to evaluate whether gaseous ozone application affects the immediate enamel bond strength or microleakage of 2 dental sealants. Methods: Sixty bovine incisors were randomly divided into 4 groups, and sealants were applied to the enamel surfaces as follows: ozone + Concise; Concise (control); ozone + UltraSeal XT Plus; and UltraSeal XT Plus (control). Ozone application was performed for 80 seconds, and shear bond strength was measured. Additionally, 60 human molars were randomly divided into 4 groups, as aforementioned, and sealants were applied onto occlusal surfaces. Dye penetration (microleakage) was assessed. Results: No significant differences were found between the 2 sealants. Ozone application did not result in a significant reduction in enamel bond strength or an increase in microleakage. Conclusions: Ozone gas did not compromise the adhesion of tested materials; therefore, one can disinfect the enamel surface before placing a dental sealant without impairing the material’s clinical performance.

Effect of Ozone Application on the Immediate Shear Bond Strength and Microleakage of Dental Sealants

MARCHESI, GIULIO;NAVARRA, CHIARA;DI LENARDA, Roberto;BRESCHI, LORENZO;CADENARO, MILENA
2012-01-01

Abstract

Purpose: The purpose of this study was to evaluate whether gaseous ozone application affects the immediate enamel bond strength or microleakage of 2 dental sealants. Methods: Sixty bovine incisors were randomly divided into 4 groups, and sealants were applied to the enamel surfaces as follows: ozone + Concise; Concise (control); ozone + UltraSeal XT Plus; and UltraSeal XT Plus (control). Ozone application was performed for 80 seconds, and shear bond strength was measured. Additionally, 60 human molars were randomly divided into 4 groups, as aforementioned, and sealants were applied onto occlusal surfaces. Dye penetration (microleakage) was assessed. Results: No significant differences were found between the 2 sealants. Ozone application did not result in a significant reduction in enamel bond strength or an increase in microleakage. Conclusions: Ozone gas did not compromise the adhesion of tested materials; therefore, one can disinfect the enamel surface before placing a dental sealant without impairing the material’s clinical performance.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2551038
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 10
social impact