Severe airflow obstruction is a common cause of acute respiratory failure. Dynamic hyperinflation affects tidal ventilation, increases airways resistance, and causes intrinsic positive end-expiratory pressure (auto-PEEP). Most patients with asthma and chronic obstructive pulmonary disease have dynamic hyperinflation and auto-PEEP during mechanical ventilation, which can cause hemodynamic compromise and barotrauma. Auto-PEEP can be identified in passively breathing patients by observation of real-time ventilator flow and pressure graphics. In spontaneously breathing patients, auto-PEEP is measured by simultaneous recordings of esophageal and flow waveforms. The ventilatory pattern should be directed toward minimizing dynamic hyperinflation and auto-PEEP by using small tidal volume and preserving expiratory time. With a spontaneously breathing patient, to reduce the work of breathing and improve patient-ventilator interaction, it is crucial to set an adequate inspiratory flow, inspiratory time, trigger sensitivity, and ventilator-applied PEEP. Ventilator graphics are invaluable for monitoring and treatment decisions at the bedside.

Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic hyperinflation in mechanically ventilated patients.

LUCANGELO, UMBERTO
2005-01-01

Abstract

Severe airflow obstruction is a common cause of acute respiratory failure. Dynamic hyperinflation affects tidal ventilation, increases airways resistance, and causes intrinsic positive end-expiratory pressure (auto-PEEP). Most patients with asthma and chronic obstructive pulmonary disease have dynamic hyperinflation and auto-PEEP during mechanical ventilation, which can cause hemodynamic compromise and barotrauma. Auto-PEEP can be identified in passively breathing patients by observation of real-time ventilator flow and pressure graphics. In spontaneously breathing patients, auto-PEEP is measured by simultaneous recordings of esophageal and flow waveforms. The ventilatory pattern should be directed toward minimizing dynamic hyperinflation and auto-PEEP by using small tidal volume and preserving expiratory time. With a spontaneously breathing patient, to reduce the work of breathing and improve patient-ventilator interaction, it is crucial to set an adequate inspiratory flow, inspiratory time, trigger sensitivity, and ventilator-applied PEEP. Ventilator graphics are invaluable for monitoring and treatment decisions at the bedside.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2615839
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 24
  • Scopus 113
  • ???jsp.display-item.citation.isi??? ND
social impact