The PERCIVAL ("Pixelated Energy Resolving CMOS Imager, Versatile and Large") is a collaboration of DESY, RAL/STFC, ELETTRA, and DLS to develop a monolithic active pixel sensor (MAPS) to provide a suitable detector for photon science for the photon energy regime between 250 eV and 1 keV. An important performance parameter is the spatial resolution which can be inferred from the Modulation Transfer Function (MTF). The MTF measures in optical systems the relative contrast of a pattern in function of the spatial frequency. With a back-thinned and back-illuminated PERCIVAL prototype chip, dedicated MTF evaluation data were taken at Elettra's TwinMic Beamline in March 2014 at a photon energy of 535 eV. We will present our MTF derivation approaches together with MTF results for 3 pixel types of the irradiated test sensor
Spatial resolution studies for the PERCIVAL sensor / Viti, M., Bayer, M., Correa, J., Göttlicher, P., Lange, S., Marras, A., Shevyakov, I., Smoljanin, S., Tennert, M., Wunderer, C.B., Xia, Q., Zimmer, M., Das, D., Guerrini, N., Marsh, B., Sedgwick, I., Turchetta, R., Cautero, G., Gianoncelli, A., Giuressi, D., et al.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - ELETTRONICO. - 10:1(2015), pp. C01044.--C01044.-. [10.1088/1748-0221/10/01/C01044]
Spatial resolution studies for the PERCIVAL sensor
CAUTERO, GIUSEPPE;GIURESSI, DARIO;MENK, RALF HENDRIK;
2015-01-01
Abstract
The PERCIVAL ("Pixelated Energy Resolving CMOS Imager, Versatile and Large") is a collaboration of DESY, RAL/STFC, ELETTRA, and DLS to develop a monolithic active pixel sensor (MAPS) to provide a suitable detector for photon science for the photon energy regime between 250 eV and 1 keV. An important performance parameter is the spatial resolution which can be inferred from the Modulation Transfer Function (MTF). The MTF measures in optical systems the relative contrast of a pattern in function of the spatial frequency. With a back-thinned and back-illuminated PERCIVAL prototype chip, dedicated MTF evaluation data were taken at Elettra's TwinMic Beamline in March 2014 at a photon energy of 535 eV. We will present our MTF derivation approaches together with MTF results for 3 pixel types of the irradiated test sensor| File | Dimensione | Formato | |
|---|---|---|---|
|
2864991.pdf
Accesso chiuso
Tipologia:
Documento in Versione Editoriale
Licenza:
Digital Rights Management non definito
Dimensione
3.66 MB
Formato
Adobe PDF
|
3.66 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


