Palytoxin (PLTX) and its analogues have been detected as seafood contaminants associated with a series of human foodborne poisonings. Due to a number of fatalities ascribed to the ingestion of PLTXcontaminated marine organisms, the development of methods for its detection in seafood has been recommended by the European Food Safety Authority (EFSA). Due to its feasibility, the spectrophotometric hemolytic assay is widely used to detect PLTX in different matrices, even though a standardized protocol is still lacking. Thus, on the basis of available assay procedures, a new standardized protocol was set up using purified human erythrocytes exposed to PLTX (working range: 3.9 1010e2.5 108 M) in a Kþ-free phosphate buffered saline solution, employing a 5 h incubation at 41 C. An intra-laboratory characterization demonstrated its sensitivity (limit of detection, LOD ¼ 1.4 1010 M and quantitation, LOQ ¼ 3.4 1010 M), accuracy (bias ¼ 0.8%), repeatability (RSDr ¼ 15% and 6% for intra- and inter-day repeatability, respectively) and specificity. However, the standardized method seems not to be suitable for PLTX quantitation in complex matrices, such as mussel (Mytilus galloprovincialis) extracts, at least below the limit suggested by EFSA (30 mg PLTXs/Kg shellfish meat). Thus, the hemolytic assay for PLTX quantitation in seafood should be used only after a careful evaluation of the specific matrix effects.
A revisited hemolytic assay for palytoxin detection: Limitations for its quantitation in mussels
BROVEDANI, VALENTINA;SOSA, SILVIO;TUBARO, AURELIA;PELIN, MARCO
2016-01-01
Abstract
Palytoxin (PLTX) and its analogues have been detected as seafood contaminants associated with a series of human foodborne poisonings. Due to a number of fatalities ascribed to the ingestion of PLTXcontaminated marine organisms, the development of methods for its detection in seafood has been recommended by the European Food Safety Authority (EFSA). Due to its feasibility, the spectrophotometric hemolytic assay is widely used to detect PLTX in different matrices, even though a standardized protocol is still lacking. Thus, on the basis of available assay procedures, a new standardized protocol was set up using purified human erythrocytes exposed to PLTX (working range: 3.9 1010e2.5 108 M) in a Kþ-free phosphate buffered saline solution, employing a 5 h incubation at 41 C. An intra-laboratory characterization demonstrated its sensitivity (limit of detection, LOD ¼ 1.4 1010 M and quantitation, LOQ ¼ 3.4 1010 M), accuracy (bias ¼ 0.8%), repeatability (RSDr ¼ 15% and 6% for intra- and inter-day repeatability, respectively) and specificity. However, the standardized method seems not to be suitable for PLTX quantitation in complex matrices, such as mussel (Mytilus galloprovincialis) extracts, at least below the limit suggested by EFSA (30 mg PLTXs/Kg shellfish meat). Thus, the hemolytic assay for PLTX quantitation in seafood should be used only after a careful evaluation of the specific matrix effects.File | Dimensione | Formato | |
---|---|---|---|
Toxicon hemolytic assay 2016.pdf
Accesso chiuso
Descrizione: Articolo principale
Tipologia:
Documento in Versione Editoriale
Licenza:
Digital Rights Management non definito
Dimensione
917.35 kB
Formato
Adobe PDF
|
917.35 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Brovedani et al Toxicon 2016 postprint.pdf
Open Access dal 24/06/2017
Tipologia:
Bozza finale post-referaggio (post-print)
Licenza:
Creative commons
Dimensione
1.45 MB
Formato
Adobe PDF
|
1.45 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.