Architectural trends to include transparency in structural systems lead to the implementation, in the last decades, of structural glass load-bearing components able to substitute traditional construction materials like timber, steel, concrete.In this paper, the structural bending performance of post-tensioned, glass-FRP hybrid beams is evaluated by means of advanced Finite-Element (FE) numerical analyses. To this aim, a concise recapitulation of existing research on several typologies of glass-FRP hybrid beams is first provided. Based on earlier experimental and preliminary FE research outcomes, further detailed discussion is then proposed for the specific concept of glass-FRP post-tensioned glass beams. FE parametric simulations for quasi-static bending loading configuration and room temperature are compared for such systems, typically including a laminated glass (LG) cross-section and an adhesively connected, post-tensioning FRP tendon. As shown, several aspects should be properly taken into account when investigating the overall performance of these systems, as far as both their elastic and post-cracked performance are highly sensitive to various mechanical and geometrical input parameters. A sensitivity FE study is hence presented, aiming to better explore their typical performance.

Numerical analysis of glass-FRP post-tensioned beams – Review and assessment

BEDON, CHIARA;
2017-01-01

Abstract

Architectural trends to include transparency in structural systems lead to the implementation, in the last decades, of structural glass load-bearing components able to substitute traditional construction materials like timber, steel, concrete.In this paper, the structural bending performance of post-tensioned, glass-FRP hybrid beams is evaluated by means of advanced Finite-Element (FE) numerical analyses. To this aim, a concise recapitulation of existing research on several typologies of glass-FRP hybrid beams is first provided. Based on earlier experimental and preliminary FE research outcomes, further detailed discussion is then proposed for the specific concept of glass-FRP post-tensioned glass beams. FE parametric simulations for quasi-static bending loading configuration and room temperature are compared for such systems, typically including a laminated glass (LG) cross-section and an adhesively connected, post-tensioning FRP tendon. As shown, several aspects should be properly taken into account when investigating the overall performance of these systems, as far as both their elastic and post-cracked performance are highly sensitive to various mechanical and geometrical input parameters. A sensitivity FE study is hence presented, aiming to better explore their typical performance.
File in questo prodotto:
File Dimensione Formato  
FRP_fin.pdf

Open Access dal 28/06/2019

Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 9.27 MB
Formato Adobe PDF
9.27 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2907104
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 22
social impact