The main purpose of this study was to determine the efficacy of Watch-PAT in Pediatric Sleep Disordered Breathing (PSDB) diagnosis in children with symptoms suggestive of PSDB, in which the nocturnal pulse oximetry was negative according to the Brouilette criteria. METHODS: We enrolled 28 patients aged between 5 and 12 years (mean age: 7.75 ± 1.69), who underwent the registration with Watch-PAT, that utilizes the Peripheral Arterial Tone (PAT), AHI, RDI, body position, snoring, pulse oximetry and actigraphy. RESULTS: Recording Watch-PAT was indicative of PSDB in 10/28 (35.7%) patients; when it was placed the threshold of AHI > 1 the number of positive patients for PSDB increased to 17/28 (60.7%). Exists a positive correlation between pat-RDI (rho = 0.798, p = 0.005) and the snoring > 40% of the time (rho = 0.656, p < 0.001) were correlated with the pat-AHI values. CONCLUSION: The recording Watch-PAT appears to permit the defection of a certain number of SDB that might escape to the clinical evaluation and pulse oximetry only.

The watch-pat in pediatrics sleep disordered breathing: Pilot study on children with negative nocturnal pulse oximetry

SPINATO, GIACOMO;TIRELLI, GIAN CARLO;
2017-01-01

Abstract

The main purpose of this study was to determine the efficacy of Watch-PAT in Pediatric Sleep Disordered Breathing (PSDB) diagnosis in children with symptoms suggestive of PSDB, in which the nocturnal pulse oximetry was negative according to the Brouilette criteria. METHODS: We enrolled 28 patients aged between 5 and 12 years (mean age: 7.75 ± 1.69), who underwent the registration with Watch-PAT, that utilizes the Peripheral Arterial Tone (PAT), AHI, RDI, body position, snoring, pulse oximetry and actigraphy. RESULTS: Recording Watch-PAT was indicative of PSDB in 10/28 (35.7%) patients; when it was placed the threshold of AHI > 1 the number of positive patients for PSDB increased to 17/28 (60.7%). Exists a positive correlation between pat-RDI (rho = 0.798, p = 0.005) and the snoring > 40% of the time (rho = 0.656, p < 0.001) were correlated with the pat-AHI values. CONCLUSION: The recording Watch-PAT appears to permit the defection of a certain number of SDB that might escape to the clinical evaluation and pulse oximetry only.
File in questo prodotto:
File Dimensione Formato  
The watch-pat in pediatrics sleep disordered breathing2017.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 668.78 kB
Formato Adobe PDF
668.78 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2909063
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact