Cross-laminated timber (CLT) wall systems are composed of massive timber panels that are fastened together and to the horizontal elements (foundations or intermediate floors) with step joints and mechanical connections. Due to the high in-plane stiffness of CLT, the shear response of such systems depends strongly on the connections used. This paper proposes a numerical model capable of predicting the mechanical behavior and failure mechanisms of CLT wall systems. The wall and the element to which it is anchored are simulated using three-dimensional (3D) solid bodies, while the connections are modeled as nonlinear hysteretic springs. Typical racking tests of wall systems are reproduced by varying the assumptions used to schematize the behavior of the connections. Results are compared with test data published in the literature, and the differences are discussed. The influence of the boundary conditions (vertical load applied on top of the wall and friction at its base) and aspect ratio of the panel are investigated via a parametric numerical study. Finally, the performance of a wall system assembled with two CLT panels is analyzed, highlighting how the properties of the anchoring connections and vertical step joints affect the load-displacement response and energy dissipation

Investigating the hysteretic behavior of Cross-Laminated Timber wall systems due to connections

Matteo Izzi
;
2018-01-01

Abstract

Cross-laminated timber (CLT) wall systems are composed of massive timber panels that are fastened together and to the horizontal elements (foundations or intermediate floors) with step joints and mechanical connections. Due to the high in-plane stiffness of CLT, the shear response of such systems depends strongly on the connections used. This paper proposes a numerical model capable of predicting the mechanical behavior and failure mechanisms of CLT wall systems. The wall and the element to which it is anchored are simulated using three-dimensional (3D) solid bodies, while the connections are modeled as nonlinear hysteretic springs. Typical racking tests of wall systems are reproduced by varying the assumptions used to schematize the behavior of the connections. Results are compared with test data published in the literature, and the differences are discussed. The influence of the boundary conditions (vertical load applied on top of the wall and friction at its base) and aspect ratio of the panel are investigated via a parametric numerical study. Finally, the performance of a wall system assembled with two CLT panels is analyzed, highlighting how the properties of the anchoring connections and vertical step joints affect the load-displacement response and energy dissipation
2018
1-mag-2018
Pubblicato
https://ascelibrary.org/doi/10.1061/%28ASCE%29ST.1943-541X.0002022
File in questo prodotto:
File Dimensione Formato  
JOUR_Izzi_2018c.pdf

Accesso chiuso

Descrizione: Articolo pubblicato
Tipologia: Documento in Versione Editoriale
Licenza: Copyright Editore
Dimensione 2.43 MB
Formato Adobe PDF
2.43 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2919177
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 52
  • ???jsp.display-item.citation.isi??? 44
social impact