BACKGROUND: Current international guidelines state that heart rate counted at the brachial pulse must be absent or <60 b x min(-1) to diagnose cardiac arrest. Some data suggest that this site may not be the best to check cardiac activity. Hypotension is a likely real scenario of the need for chest compressions in infants. We compared the performance of three sites of pulse palpation (brachial, carotid, and femoral) for detecting and counting heartbeat in hypotensive infants. METHODS: In an operating theater of a pediatric teaching hospital in Italy, we studied 40 anesthetized hypotensive infants just prior to surgery, checked by two doctors and two nurses by a cross-sectional, repeated-measures study design. Each examiner, blind to the monitoring data of the patient, was asked to find the infant's arterial pulse within 10 s and count heart rate for 15 s. During each examination, the order of the three sites was randomized. RESULTS: Among successful detections, femoral pulse palpation resulted as the most successful, rapid, and accurate site to detect and count heart rate in hypotensive infants. CONCLUSIONS: Femoral palpation proved to be the best site for detecting heartbeat and counting heart rate in hypotensive infants. These findings challenge the current guidelines. More data are needed, but the current standard of brachial pulse assessment is debatable.

Comparison of three sites to check the pulse and count heart rate in hypotensive infants

Ronfani, Luca;Barbi, Egidio
2006-01-01

Abstract

BACKGROUND: Current international guidelines state that heart rate counted at the brachial pulse must be absent or <60 b x min(-1) to diagnose cardiac arrest. Some data suggest that this site may not be the best to check cardiac activity. Hypotension is a likely real scenario of the need for chest compressions in infants. We compared the performance of three sites of pulse palpation (brachial, carotid, and femoral) for detecting and counting heartbeat in hypotensive infants. METHODS: In an operating theater of a pediatric teaching hospital in Italy, we studied 40 anesthetized hypotensive infants just prior to surgery, checked by two doctors and two nurses by a cross-sectional, repeated-measures study design. Each examiner, blind to the monitoring data of the patient, was asked to find the infant's arterial pulse within 10 s and count heart rate for 15 s. During each examination, the order of the three sites was randomized. RESULTS: Among successful detections, femoral pulse palpation resulted as the most successful, rapid, and accurate site to detect and count heart rate in hypotensive infants. CONCLUSIONS: Femoral palpation proved to be the best site for detecting heartbeat and counting heart rate in hypotensive infants. These findings challenge the current guidelines. More data are needed, but the current standard of brachial pulse assessment is debatable.
2006
Pubblicato
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2920448
 Avviso

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 24
social impact