n modern constructions, service equipment is the most used and complex technology. Air and liquid flow inside piping or conduit provides conditioning, well-being and comfort within buildings. Nevertheless, fluid movements inject both structure-borne and airborne noise, causing annoyance on people living inside edifices. In order to avoid this issue, the model provided by ISO 12354-5 standard could be used. Unfortunately, the standard describes very well the process in order to calculate the resulting noise caused by air flow service equipment, but it does not offer clear definitions of parameters related to waste water installations. As a consequence, very few researches and studies are available at present because of the difficulty on initial data set and on interpretation of requested parameters. In this article, the ISO 12354-5 method for waste water pipe source is critically analysed, modified and then applied to real case studies. Considerations on coupling terms are proposed, discussed and used in the standard equations, calculating the theoretical values and providing possible solutions for all missing data; results demonstrate how the suggested modified models matched very well measurements outcomes.
The use of numerical models on service equipment noise prediction in heavyweight timber buildings
Marco Caniato;BETTARELLO, FEDERICA;Chiara Schmid;Patrizio Fausti
2018-01-01
Abstract
n modern constructions, service equipment is the most used and complex technology. Air and liquid flow inside piping or conduit provides conditioning, well-being and comfort within buildings. Nevertheless, fluid movements inject both structure-borne and airborne noise, causing annoyance on people living inside edifices. In order to avoid this issue, the model provided by ISO 12354-5 standard could be used. Unfortunately, the standard describes very well the process in order to calculate the resulting noise caused by air flow service equipment, but it does not offer clear definitions of parameters related to waste water installations. As a consequence, very few researches and studies are available at present because of the difficulty on initial data set and on interpretation of requested parameters. In this article, the ISO 12354-5 method for waste water pipe source is critically analysed, modified and then applied to real case studies. Considerations on coupling terms are proposed, discussed and used in the standard equations, calculating the theoretical values and providing possible solutions for all missing data; results demonstrate how the suggested modified models matched very well measurements outcomes.File | Dimensione | Formato | |
---|---|---|---|
caniato2018.pdf
Accesso chiuso
Tipologia:
Documento in Versione Editoriale
Licenza:
Copyright Editore
Dimensione
1.15 MB
Formato
Adobe PDF
|
1.15 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.