Background: Piezosurgery is a surgical procedure that is able to perform osteotomies by a micrometric and selective cut of the bone tissue. The objective of this investigation was to evaluate two different techniques; an ultrasonic device, and a drill approach for implant site preparation. Methods: A total of fifty patients were recruited for the randomized clinical trial to receive dental implants for fixed prosthetic restoration in the posterior mandible and were allotted to two groups. In Group A the implant site was prepared following a drilling technique, while in Group B the implant site was prepared using an ultrasonic device; moreover, the operative duration was recorded. Postoperative pain and swelling were evaluated at 1, 2, 4, and 6 days. The crestal bone resorption was measured at 3 months from implant placement by a three-dimensional tomography evaluation. Results: The findings suggest that osteotomies performed by an ultrasonic device cause less pain and swelling. On the other hand, the piezoelectric preparation was characterized by a significative increase in the operative time. No statistical differences in crestal bone resorption were evident in the two different approaches. Conclusions: According to the outcome of the study, ultrasonic implant bed preparation can be used with success in implantology and could be considered a suitable alternative to traditional drilling techniques for dental fixture placement.

Ultrasonic vs Drill Implant Site Preparation: Post-Operative Pain Measurement Through VAS, Swelling and Crestal Bone Remodeling: A Randomized Clinical Study.

Lorenzo Bevilacqua;Michele Maglione
2018-01-01

Abstract

Background: Piezosurgery is a surgical procedure that is able to perform osteotomies by a micrometric and selective cut of the bone tissue. The objective of this investigation was to evaluate two different techniques; an ultrasonic device, and a drill approach for implant site preparation. Methods: A total of fifty patients were recruited for the randomized clinical trial to receive dental implants for fixed prosthetic restoration in the posterior mandible and were allotted to two groups. In Group A the implant site was prepared following a drilling technique, while in Group B the implant site was prepared using an ultrasonic device; moreover, the operative duration was recorded. Postoperative pain and swelling were evaluated at 1, 2, 4, and 6 days. The crestal bone resorption was measured at 3 months from implant placement by a three-dimensional tomography evaluation. Results: The findings suggest that osteotomies performed by an ultrasonic device cause less pain and swelling. On the other hand, the piezoelectric preparation was characterized by a significative increase in the operative time. No statistical differences in crestal bone resorption were evident in the two different approaches. Conclusions: According to the outcome of the study, ultrasonic implant bed preparation can be used with success in implantology and could be considered a suitable alternative to traditional drilling techniques for dental fixture placement.
2018
Pubblicato
https://www.mdpi.com/1996-1944/11/12/2516
File in questo prodotto:
File Dimensione Formato  
materials-11-02516.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 1.23 MB
Formato Adobe PDF
1.23 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2935709
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 36
social impact