BACKGROUND: Superficial wounds that require suturing are often the reason children visit the Paediatric Emergency Department. Suturing is usually accompanied by perilesional administration of lidocaine, a local anaesthetic drug that improves pain tolerance. In paediatric patients, this approach has a low compliance because lidocaine has to be injected, which in children generates fear and anxiety, a sterile anaesthetic gel could improve the child compliance. OBJECTIVE: To develop a sterile and stable sterile gel capable of remaining in place over time for topical anaesthesia. METHOD: Different formulations were analysed by HPLC, by UV and fluorimetric detection. Two different sterilisation methods were tested. MAIN OUTCOME: To maintain the original stability of the gel also after sterilisation process. RESULTS: Four different gels were prepared and analysed; the most stable gel lasts over 3 months with a degradation less than 10%. CONCLUSION: The use of Poloxamer 407 guarantees stability of the preparation, showing a reduction in oxidative reaction, and gives the gel the right texture for application to a bleeding wound.

Stability of a novel Lidocaine, Adrenaline and Tetracaine sterile thermosensitive gel: A ready-to-use formulation

Zanon, Davide
;
VOLPATO, CHIARA;ADDOBBATI, RICCARDO;Maestro, Alessandra;Barbi, Egidio;Maximova, Natalia;Mamolo, Maria Grazia;Zampieri, Daniele
2019-01-01

Abstract

BACKGROUND: Superficial wounds that require suturing are often the reason children visit the Paediatric Emergency Department. Suturing is usually accompanied by perilesional administration of lidocaine, a local anaesthetic drug that improves pain tolerance. In paediatric patients, this approach has a low compliance because lidocaine has to be injected, which in children generates fear and anxiety, a sterile anaesthetic gel could improve the child compliance. OBJECTIVE: To develop a sterile and stable sterile gel capable of remaining in place over time for topical anaesthesia. METHOD: Different formulations were analysed by HPLC, by UV and fluorimetric detection. Two different sterilisation methods were tested. MAIN OUTCOME: To maintain the original stability of the gel also after sterilisation process. RESULTS: Four different gels were prepared and analysed; the most stable gel lasts over 3 months with a degradation less than 10%. CONCLUSION: The use of Poloxamer 407 guarantees stability of the preparation, showing a reduction in oxidative reaction, and gives the gel the right texture for application to a bleeding wound.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0928098719302258-main.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Copyright Editore
Dimensione 2.1 MB
Formato Adobe PDF
2.1 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2946442
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact