Butyltin compound (BTC) contamination was evaluated in two north Adriatic marinas, San Rocco (Italy) and Lucija (Slovenia). BTC sedimentary concentrations (121 ± 46 and 352 ± 30 ng Sn g−1 in San Rocco and Lucija, respectively) evidenced the past use of antifouling paints, confirmed by the reduced tributyltin content (~ 46%) with respect to the sumof BTC. Elemental and organic carbon isotopic (δ13C) analyses of bulk sediments and its lipid and humic substances were performed in order to evaluate their role in BTC partitioning and preservation. The δ13C of sedimentary bulk and refractory organic matter suggested that diagenetic processes could play a role in the preservation or release of pollutants. No contamination was found in water collected from the benthic chamber and thus, fluxes at the sediment-water interface were not assessed, except for MBT efflux at Lucija (28.9 ng Sn m−2 day−1). Nevertheless, BTC concentrations in porewaters (up to 75 ng Sn l−1) and rather low sediment-porewater partitioning coefficients (Kd) with respect to the data reported in the literature would suggest a potential risk of the reintroduction of BTC into the water column at both sites: at Lucija, sedimentary contamination is high despite the greater Log Kd, whilst at San Rocco, the low BTC concentration is associated with a reduced sediment affinity.
Organotin compounds in touristic marinas of the northern Adriatic Sea: occurrence, speciation and potential recycling at the sediment-water interface
Elisa Petranich;Matteo Crosera;Stefano Covelli;BERTO, DANIELA
2019-01-01
Abstract
Butyltin compound (BTC) contamination was evaluated in two north Adriatic marinas, San Rocco (Italy) and Lucija (Slovenia). BTC sedimentary concentrations (121 ± 46 and 352 ± 30 ng Sn g−1 in San Rocco and Lucija, respectively) evidenced the past use of antifouling paints, confirmed by the reduced tributyltin content (~ 46%) with respect to the sumof BTC. Elemental and organic carbon isotopic (δ13C) analyses of bulk sediments and its lipid and humic substances were performed in order to evaluate their role in BTC partitioning and preservation. The δ13C of sedimentary bulk and refractory organic matter suggested that diagenetic processes could play a role in the preservation or release of pollutants. No contamination was found in water collected from the benthic chamber and thus, fluxes at the sediment-water interface were not assessed, except for MBT efflux at Lucija (28.9 ng Sn m−2 day−1). Nevertheless, BTC concentrations in porewaters (up to 75 ng Sn l−1) and rather low sediment-porewater partitioning coefficients (Kd) with respect to the data reported in the literature would suggest a potential risk of the reintroduction of BTC into the water column at both sites: at Lucija, sedimentary contamination is high despite the greater Log Kd, whilst at San Rocco, the low BTC concentration is associated with a reduced sediment affinity.File | Dimensione | Formato | |
---|---|---|---|
Formalewicz_et_al_2019_in_press.pdf
Accesso chiuso
Descrizione: articolo principale
Tipologia:
Documento in Versione Editoriale
Licenza:
Copyright Editore
Dimensione
1.07 MB
Formato
Adobe PDF
|
1.07 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.