Background and aim of the work: Partial or total hip replacement is the method of choice for displaced femoral neck fractures (FNF) treatment. Dislocation is a major complication, accounting for about 3.8% of cases for hemiarthroplasty (HA) and 10% for total hip arthroplasty (THA). Dual-mobility (DM) socket in total hip arthroplasty showed a very low rate of dislocation in both primary and revision setting THA. Some literature reports show good results with low dislocation rates also in FNF treatment at short term follow-up. Aim of the study was to evaluate clinical and radiographic results of DM-THA in FNF treatment at mid-term follow up. Methods: Study population counted 31 implants in 30 patients treated with DM-THA for FNF between January 2010 and December 2012. Dislocation rate was identified, and HHS and OHS were completed. Twenty-four patients underwent also radiographic evaluation to assess cup integration and sings of loosening. Results: No episodes of hip dislocation nor intraprosthetic dislocation were found. Other postoperative complications were recorded in 9,67%. HHS and OHS showed a mean value of 81,22 and 37,37, respectively. There were no cases of clinical and radiographic signs of implant loosening. Conclusions: The present study confirms the good clinical results, low complications and very low dislocation rate with DM THA for FNF treatment.

Dual mobility total hip arthroplasty in the treatment of femoral neck fractures: A retrospective evaluation at mid-term follow-up

Canton G.
;
Moghnie A.;Cleva M.;Kostoris F. M.;Murena L.
2019-01-01

Abstract

Background and aim of the work: Partial or total hip replacement is the method of choice for displaced femoral neck fractures (FNF) treatment. Dislocation is a major complication, accounting for about 3.8% of cases for hemiarthroplasty (HA) and 10% for total hip arthroplasty (THA). Dual-mobility (DM) socket in total hip arthroplasty showed a very low rate of dislocation in both primary and revision setting THA. Some literature reports show good results with low dislocation rates also in FNF treatment at short term follow-up. Aim of the study was to evaluate clinical and radiographic results of DM-THA in FNF treatment at mid-term follow up. Methods: Study population counted 31 implants in 30 patients treated with DM-THA for FNF between January 2010 and December 2012. Dislocation rate was identified, and HHS and OHS were completed. Twenty-four patients underwent also radiographic evaluation to assess cup integration and sings of loosening. Results: No episodes of hip dislocation nor intraprosthetic dislocation were found. Other postoperative complications were recorded in 9,67%. HHS and OHS showed a mean value of 81,22 and 37,37, respectively. There were no cases of clinical and radiographic signs of implant loosening. Conclusions: The present study confirms the good clinical results, low complications and very low dislocation rate with DM THA for FNF treatment.
File in questo prodotto:
File Dimensione Formato  
8070-Article Text-32838-3-10-20190121.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 779.69 kB
Formato Adobe PDF
779.69 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2962157
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 22
  • ???jsp.display-item.citation.isi??? ND
social impact