Bioresorbable scaffolds have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by persistent metallic foreign body. Early clinical studies using the first commercially available drug-eluting bioresorbable vascular scaffold (BVS) reported very promising safety and efficacy outcomes, comparable to best-in-class second-generation drug-eluting metal stent. To date, more than 60,000 Absorb BVSs have been implanted with only the interim analysis of one randomized trial (ABSORB II RCT) available. Recent registries have challenged the initial claim that BVS is immune from Scaffold Thrombosis (ST). However, suboptimal device expansion and insufficient intracoronary imaging guidance can explain higher than expected ST, especially in complex lesions. The aim of this review article is to critically evaluate the results of the available Absorb BVS studies and discuss the lessons learned to optimize lesion selection and implantation technique of such devices.

Absorb bioresorbable vascular scaffold: What have we learned after 5 years of clinical experience?

Fabris E.;
2015-01-01

Abstract

Bioresorbable scaffolds have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by persistent metallic foreign body. Early clinical studies using the first commercially available drug-eluting bioresorbable vascular scaffold (BVS) reported very promising safety and efficacy outcomes, comparable to best-in-class second-generation drug-eluting metal stent. To date, more than 60,000 Absorb BVSs have been implanted with only the interim analysis of one randomized trial (ABSORB II RCT) available. Recent registries have challenged the initial claim that BVS is immune from Scaffold Thrombosis (ST). However, suboptimal device expansion and insufficient intracoronary imaging guidance can explain higher than expected ST, especially in complex lesions. The aim of this review article is to critically evaluate the results of the available Absorb BVS studies and discuss the lessons learned to optimize lesion selection and implantation technique of such devices.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0167527315302230-main.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Copyright Editore
Dimensione 811.56 kB
Formato Adobe PDF
811.56 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
11368_2962640_print.pdf

accesso aperto

Tipologia: Bozza finale post-referaggio (post-print)
Licenza: Digital Rights Management non definito
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2962640
Citazioni
  • ???jsp.display-item.citation.pmc??? 17
  • Scopus 62
  • ???jsp.display-item.citation.isi??? 57
social impact