Background Recent evidence has raised concerns regarding the safety of the everolimus-eluting bioresorbable vascular scaffold (E-BVS) (Absorb, Abbott Vascular, Santa Clara, CA, USA). Following these data, the use of this device has diminished in the Netherlands; however, daily practice data are limited. Therefore we studied the incidence of safety and efficacy outcomes with this device in daily clinical practice in a single large tertiary centre in the Netherlands. Methods All E-BVS treated patients were included in this analysis. The primary endpoint was target lesion failure (TLF), a composite of cardiac death, target vessel non-fatal myocardial infarction (TV-MI) and clinically-driven target lesion revascularisation (TLR). The secondary endpoint was the incidence of definite scaffold thrombosis. Results Between October 2013 and January 2017, 105 patients were treated with 147 E-BVS. This population contained 42 (40%) patients with diabetes mellitus and 43 (40.9%) undergoing treatment for acute coronary syndrome, and thus represents a high-risk patient cohort. Mean follow-up was 19.8 months. Intravascular imaging guidance during scaffold implantation was used in 64/105 (43.5%) patients. The primary endpoint (TLF) occurred in 3 (2.9%) patients. All-cause mortality and cardiac mortality occurred in 2 (2%) and 0 (0%) patients respectively. TV-MI occurred in 2 patients (1.9%): both were periprocedural and not related to the BVS implantation. TLR occurred in 1 patient (1.0%) during follow-up. No definite scaffold thrombosis occurred during follow-up. Conclusion This single-centre study examining the real-world experience of E-BVS implantation in a high-risk population shows excellent procedural safety and long-term clinical outcomes.

Everolimus-eluting bioresorbable vascular scaffold in daily clinical practice: A single-centre experience

Fabris E.;
2017-01-01

Abstract

Background Recent evidence has raised concerns regarding the safety of the everolimus-eluting bioresorbable vascular scaffold (E-BVS) (Absorb, Abbott Vascular, Santa Clara, CA, USA). Following these data, the use of this device has diminished in the Netherlands; however, daily practice data are limited. Therefore we studied the incidence of safety and efficacy outcomes with this device in daily clinical practice in a single large tertiary centre in the Netherlands. Methods All E-BVS treated patients were included in this analysis. The primary endpoint was target lesion failure (TLF), a composite of cardiac death, target vessel non-fatal myocardial infarction (TV-MI) and clinically-driven target lesion revascularisation (TLR). The secondary endpoint was the incidence of definite scaffold thrombosis. Results Between October 2013 and January 2017, 105 patients were treated with 147 E-BVS. This population contained 42 (40%) patients with diabetes mellitus and 43 (40.9%) undergoing treatment for acute coronary syndrome, and thus represents a high-risk patient cohort. Mean follow-up was 19.8 months. Intravascular imaging guidance during scaffold implantation was used in 64/105 (43.5%) patients. The primary endpoint (TLF) occurred in 3 (2.9%) patients. All-cause mortality and cardiac mortality occurred in 2 (2%) and 0 (0%) patients respectively. TV-MI occurred in 2 patients (1.9%): both were periprocedural and not related to the BVS implantation. TLR occurred in 1 patient (1.0%) during follow-up. No definite scaffold thrombosis occurred during follow-up. Conclusion This single-centre study examining the real-world experience of E-BVS implantation in a high-risk population shows excellent procedural safety and long-term clinical outcomes.
File in questo prodotto:
File Dimensione Formato  
Remkes2017_Article_Everolimus-elutingBioresorbabl.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 1 MB
Formato Adobe PDF
1 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2962682
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact