Background: Nasopharyngoscope reprocessing methods should be effective, rapid and reproducible with moderate cost. Tristel Trio Wipes system (TTWS) is a manual reprocessing method based on chlorine dioxide that has lately emerged in ENT department. This review aims to collect evidence on this system. Methods: The PubMed, Web of Science and Cochrane Library databases were searched for all the studies on TTWS or one of its components. Data were grouped according to the study type. Results: Ten articles were included in the review. TTWS ensured high-level disinfection in laboratory and clinical setting. Although the limitations of the manual systems, TTWS proved to be faster than automated endoscope reprocessing (AER) and safe for patients and health-care workers. TTWS represented cheaper system than AER or sheaths in low- and medium-volume centers. Conclusion: TTWS could be a valid, safe and fast HLD method for nasopharyngoscopes, with reasonable costs for medium-low reprocessing volumes.
Disposable chlorine dioxide wipes for high-level disinfection in the ENT department: A systematic review
Tofanelli M.;Capriotti V.;Marcuzzo A. V.;Boscolo-Rizzo P.;Tirelli G.
2020-01-01
Abstract
Background: Nasopharyngoscope reprocessing methods should be effective, rapid and reproducible with moderate cost. Tristel Trio Wipes system (TTWS) is a manual reprocessing method based on chlorine dioxide that has lately emerged in ENT department. This review aims to collect evidence on this system. Methods: The PubMed, Web of Science and Cochrane Library databases were searched for all the studies on TTWS or one of its components. Data were grouped according to the study type. Results: Ten articles were included in the review. TTWS ensured high-level disinfection in laboratory and clinical setting. Although the limitations of the manual systems, TTWS proved to be faster than automated endoscope reprocessing (AER) and safe for patients and health-care workers. TTWS represented cheaper system than AER or sheaths in low- and medium-volume centers. Conclusion: TTWS could be a valid, safe and fast HLD method for nasopharyngoscopes, with reasonable costs for medium-low reprocessing volumes.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0196070920300867-main.pdf
Accesso chiuso
Tipologia:
Documento in Versione Editoriale
Licenza:
Copyright Editore
Dimensione
426.01 kB
Formato
Adobe PDF
|
426.01 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
11368_2972141_print.pdf
accesso aperto
Tipologia:
Bozza finale post-referaggio (post-print)
Licenza:
Digital Rights Management non definito
Dimensione
898.81 kB
Formato
Adobe PDF
|
898.81 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.