The success of ptychography and other imaging experiments at third-generation X-ray sources is apparent from their increasingly widespread application and the improving quality of the images they produce both for resolution and contrast and in terms of relaxation of experimental constraints. The wider availability of highly coherent X-rays stimulates the development of several complementary techniques which have seen limited mutual integration in recent years. This paper presents a framework in which some of the established imaging techniques – with particular regard for ptychography – are flexibly applied to tackle the variable requirements occurring at typical synchrotron experiments. In such a framework one can obtain low-resolution images of whole samples and smoothly zoom in on specific regions of interest as they are revealed by switching to a higher-resolution imaging mode. The techniques involved range from full-field microscopy, to reach the widest fields of view (>mm), to ptychography, to achieve the highest resolution (<100 nm), and have been implemented at the I13 Coherence Branchline at Diamond Light Source.

Multiscale X-ray imaging using ptychography

P. Thibault
2018-01-01

Abstract

The success of ptychography and other imaging experiments at third-generation X-ray sources is apparent from their increasingly widespread application and the improving quality of the images they produce both for resolution and contrast and in terms of relaxation of experimental constraints. The wider availability of highly coherent X-rays stimulates the development of several complementary techniques which have seen limited mutual integration in recent years. This paper presents a framework in which some of the established imaging techniques – with particular regard for ptychography – are flexibly applied to tackle the variable requirements occurring at typical synchrotron experiments. In such a framework one can obtain low-resolution images of whole samples and smoothly zoom in on specific regions of interest as they are revealed by switching to a higher-resolution imaging mode. The techniques involved range from full-field microscopy, to reach the widest fields of view (>mm), to ptychography, to achieve the highest resolution (<100 nm), and have been implemented at the I13 Coherence Branchline at Diamond Light Source.
2018
Pubblicato
http://scripts.iucr.org/cgi-bin/paper?S1600577518007221
File in questo prodotto:
File Dimensione Formato  
yn5029.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 997.59 kB
Formato Adobe PDF
997.59 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2977540
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact