The aim of this study was to assess the fluoride (F) release potential of F-containing adhesives Transbond Plus (TB+), Light Bond (LBF), and Geristore-Tenure (GS), and a control adhesive without F content, Transbond XT (TBXT), in relation to microhardness (mu H) and degree of conversion (DC). Ten specimens of each adhesive system were illuminated at 1100 mW/cm(2) for 10 and 20 sec, totalling 80 samples. Fourier transform infrared spectroscopy was used for the assessment of DC. mu H was assessed before and after four-weeks of immersion in artificial saliva (pH 4.8) at 37 degrees C. The amount of F release was monitored by a F ion-selective electrode. F release was related to adhesive system type and curing time (p<0.05) and decreased in the following order, with the subscript indicating the illumination time in sec: TB+(10)>TB+(20)>GS(10)>GS(20)>LBF10>LBF20. The decrease of mu H after four weeks of immersion in artificial saliva is related to increased release of F (r=0.651; p<0.001). TB+ had significantly superior white spot lesions preventive potential due to twice higher F ions release, but its high mu H changes raise concerns of bond strength properties. The tested materials showed low F recharge potential.

FLUORIDE RELEASE AND RECHARGE POTENTIAL OF REMINERALIZING ORTHODONTIC ADHESIVE SYSTEMS / Zrinski, M.t., Miljanic, S., Peros, K., Turco, G., Contardo, L., Spalj, S.. - In: FLUORIDE. - ISSN 0015-4725. - STAMPA. - 52:3(2019), pp. 397-403.

FLUORIDE RELEASE AND RECHARGE POTENTIAL OF REMINERALIZING ORTHODONTIC ADHESIVE SYSTEMS

Turco, G
Investigation
;
Contardo, L
Supervision
;
2019-01-01

Abstract

The aim of this study was to assess the fluoride (F) release potential of F-containing adhesives Transbond Plus (TB+), Light Bond (LBF), and Geristore-Tenure (GS), and a control adhesive without F content, Transbond XT (TBXT), in relation to microhardness (mu H) and degree of conversion (DC). Ten specimens of each adhesive system were illuminated at 1100 mW/cm(2) for 10 and 20 sec, totalling 80 samples. Fourier transform infrared spectroscopy was used for the assessment of DC. mu H was assessed before and after four-weeks of immersion in artificial saliva (pH 4.8) at 37 degrees C. The amount of F release was monitored by a F ion-selective electrode. F release was related to adhesive system type and curing time (p<0.05) and decreased in the following order, with the subscript indicating the illumination time in sec: TB+(10)>TB+(20)>GS(10)>GS(20)>LBF10>LBF20. The decrease of mu H after four weeks of immersion in artificial saliva is related to increased release of F (r=0.651; p<0.001). TB+ had significantly superior white spot lesions preventive potential due to twice higher F ions release, but its high mu H changes raise concerns of bond strength properties. The tested materials showed low F recharge potential.
File in questo prodotto:
File Dimensione Formato  
FJ2019_v52_n3Pt3_p397-403_pq.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 488.44 kB
Formato Adobe PDF
488.44 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2993513
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact