Abstract Background. Verification of the central venous catheters (CVCs) position by chest X-ray (CXR) is usually performed in the postoperative period with the risk related to possible malposition. This prospective observational study aimed to assess the diagnostic accuracy and reproducibility of ultrasound (US) and "bubble test" to detect malpositions of CVC in the preoperative setting. Methods. The study included 105 patients undergoing preoperative CVC placement. A US protocol aimed at direct visualization of the CVC was completed by a single operator and two consecutive "bubble tests" were performed independently by different physicians. Two parameters were considered: complete right atrium (RA) opacization versus visualization of "no or few bubbles" and time from agitated saline injection to visualization of micro-bubbles in the RA ("push-to-bubbles" time). Results. CXR identified 14 (13%) CVC malpositions. Vascular US showed a sensitivity of 64% and a specificity of 100% while visualization of "no or few bubbles" at bubble test yielded a sensitivity of 50% and a specificity of 100%. "Push-to-bubbles" times were approximate to 9 times longer in patients with compared to those without CVC malposition (1400 [702-2160] ms versus 167 [123-228] ms, P<0.001). A cut off value of 500 ms had a sensitivity of 100% and a specificity of 99% for CVC malposition with an inter-observer agreement of 99% (kappa 0.96, P<0.001). Conclusion. CVC malposition was observed in a sizeable proportion of patients undergoing preoperative central venous cannulation. Measurement of "push-to-bubbles" time is a fast, accurate and highly reproducible tool for verifying the correct CVC position.

Confirmation of correct central venous catheter position in the preoperative setting by echocardiographic "bubble-test"

Roman-Pognuz, E.
;
Bonaccorso, G.
2015-01-01

Abstract

Abstract Background. Verification of the central venous catheters (CVCs) position by chest X-ray (CXR) is usually performed in the postoperative period with the risk related to possible malposition. This prospective observational study aimed to assess the diagnostic accuracy and reproducibility of ultrasound (US) and "bubble test" to detect malpositions of CVC in the preoperative setting. Methods. The study included 105 patients undergoing preoperative CVC placement. A US protocol aimed at direct visualization of the CVC was completed by a single operator and two consecutive "bubble tests" were performed independently by different physicians. Two parameters were considered: complete right atrium (RA) opacization versus visualization of "no or few bubbles" and time from agitated saline injection to visualization of micro-bubbles in the RA ("push-to-bubbles" time). Results. CXR identified 14 (13%) CVC malpositions. Vascular US showed a sensitivity of 64% and a specificity of 100% while visualization of "no or few bubbles" at bubble test yielded a sensitivity of 50% and a specificity of 100%. "Push-to-bubbles" times were approximate to 9 times longer in patients with compared to those without CVC malposition (1400 [702-2160] ms versus 167 [123-228] ms, P<0.001). A cut off value of 500 ms had a sensitivity of 100% and a specificity of 99% for CVC malposition with an inter-observer agreement of 99% (kappa 0.96, P<0.001). Conclusion. CVC malposition was observed in a sizeable proportion of patients undergoing preoperative central venous cannulation. Measurement of "push-to-bubbles" time is a fast, accurate and highly reproducible tool for verifying the correct CVC position.
2015
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/3022213
 Avviso

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 27
social impact