Distribution systems are being pushed towards smarter architectures, management strategies, and controls. To develop new platforms and algorithms for distribution systems management, the University of Trieste is using its medium voltage MW-scale ring distribution system as a demonstrator. In addition to the installation of a real-time monitoring system, power system studies and analyses are required. The paper presents and compares some results concerning the power system operation in both closed (normal operation) and open (post fault operation) configurations, where the latter are identified by means of a quantitative dependability analysis. In particular, the voltage profile, the currents, and the losses in the system are studied, evaluating the impact of faults capable of opening the ring.

Comparison Between Ring and Radial Configurations of the University of Trieste Campus MV Distribution Grid

Chiandone M.;Quaia S.;Sulligoi G.;Vicenzutti A.
2022-01-01

Abstract

Distribution systems are being pushed towards smarter architectures, management strategies, and controls. To develop new platforms and algorithms for distribution systems management, the University of Trieste is using its medium voltage MW-scale ring distribution system as a demonstrator. In addition to the installation of a real-time monitoring system, power system studies and analyses are required. The paper presents and compares some results concerning the power system operation in both closed (normal operation) and open (post fault operation) configurations, where the latter are identified by means of a quantitative dependability analysis. In particular, the voltage profile, the currents, and the losses in the system are studied, evaluating the impact of faults capable of opening the ring.
File in questo prodotto:
File Dimensione Formato  
Comparison_Between_Ring_and_Radial_Configurations_of_the_University_of_Trieste_Campus_MV_Distribution_Grid.pdf

Accesso chiuso

Descrizione: articolo pubblicato
Tipologia: Documento in Versione Editoriale
Licenza: Copyright Editore
Dimensione 1.19 MB
Formato Adobe PDF
1.19 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Comparison_Between_Ring_and_Radial_Configurations_of_the_University_of_Trieste_Campus_MV_Distribution_Grid-Post_print.pdf

accesso aperto

Tipologia: Bozza finale post-referaggio (post-print)
Licenza: Digital Rights Management non definito
Dimensione 1.09 MB
Formato Adobe PDF
1.09 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/3026087
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact