Most tissues in clinical practice are formalin-fixed and paraffin-embedded for histological as well as molecular analyses. The reproducibility and uniformity of molecular analyses is strictly dependent on the quality of the biomolecules, which is highly influenced by pre-analytical processes. In this study, the effect of different fixatives was compared, including formalin, Bouin's solution, RCL2® and TAG-1™ fixatives, by stringent application of ISO standards in mouse liver tissue processing, including formalin-free transport of tissues and tissue grossing in a refrigerated environment. The effect of fixatives was studied in terms of nucleic acid quality at the time of tissue processing and after one year of tissue storage at room temperature in the dark. Furthermore, a microcomputed tomography (CT) scan analysis was applied to investigate the paraffin embedding. The results show that the application of ISO standards in tissue processing allows analysis of 400 bases amplicons from RNA and 1000 bases from DNA, even in extracts from formalin-fixed and paraffin-embedded tissues. However, after one year storage at room temperature in the dark, a degradation of the nucleic acids was observed. Nevertheless, extracts can still be analyzed, but for metachronous tests it is highly recommended to repeat the quantitation of housekeeping genes in order to standardize the extent of nucleic acid degradation.

Impact of standardization in tissue processing: the performance of different fixatives

De Martino, Eleonora;Medeot, Caterina;D'Amico, Lorenzo;Stanta, Giorgio;Bonin, Serena
2022-01-01

Abstract

Most tissues in clinical practice are formalin-fixed and paraffin-embedded for histological as well as molecular analyses. The reproducibility and uniformity of molecular analyses is strictly dependent on the quality of the biomolecules, which is highly influenced by pre-analytical processes. In this study, the effect of different fixatives was compared, including formalin, Bouin's solution, RCL2® and TAG-1™ fixatives, by stringent application of ISO standards in mouse liver tissue processing, including formalin-free transport of tissues and tissue grossing in a refrigerated environment. The effect of fixatives was studied in terms of nucleic acid quality at the time of tissue processing and after one year of tissue storage at room temperature in the dark. Furthermore, a microcomputed tomography (CT) scan analysis was applied to investigate the paraffin embedding. The results show that the application of ISO standards in tissue processing allows analysis of 400 bases amplicons from RNA and 1000 bases from DNA, even in extracts from formalin-fixed and paraffin-embedded tissues. However, after one year storage at room temperature in the dark, a degradation of the nucleic acids was observed. Nevertheless, extracts can still be analyzed, but for metachronous tests it is highly recommended to repeat the quantitation of housekeeping genes in order to standardize the extent of nucleic acid degradation.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1871678422000437-main.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 925.52 kB
Formato Adobe PDF
925.52 kB Adobe PDF Visualizza/Apri
1-s2.0-S1871678422000437-mmc1.pdf

accesso aperto

Tipologia: Altro materiale allegato
Licenza: Digital Rights Management non definito
Dimensione 526.31 kB
Formato Adobe PDF
526.31 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/3029498
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact