Aortic stiffness is an important clinical parameter for predicting cardiovascular events. Carotid-femoral pulse wave velocity (cf-PWV) has been proposed for performing this evaluation non-invasively; however, it requires dedicated equipment and experienced operators. We explored the possibility of measuring aortic stiffness using ultrasound scans of the abdominal aorta coupled with the Bramwell-Hill equation. Healthy subjects were investigated; measurements of cf-PWV were taken by arterial tonometry and aortic systo-diastolic pressure difference was estimated using a validated model. Pulsatility of an abdominal tract of aorta was assessed by automated processing of ultrasound scans. Through a Bland-Altmann analysis, we found large biases when estimating each parameter by applying the Bramwell-Hill equation to the measured values of the other two paramters (bias, +/- 1.96 SD; PWV, about 2.1 +/- 2.5 m/s; pulsatility, 12 +/- 14%; pressure jump, 47 +/- 55 mmHg). These results indicate that the two measures are not interchangeable, and that a large part of the bias is attributable to blood pressure estimation. Further studies are needed to identify the possible sources of bias between cf-PWV and aortic pulsatility.

Estimation of Aortic Stiffness with Bramwell-Hill Equation: A Comparative Analysis with Carotid-Femoral Pulse Wave Velocity

Albani, Stefano;Grillo, Andrea;Fabris, Bruno;
2022-01-01

Abstract

Aortic stiffness is an important clinical parameter for predicting cardiovascular events. Carotid-femoral pulse wave velocity (cf-PWV) has been proposed for performing this evaluation non-invasively; however, it requires dedicated equipment and experienced operators. We explored the possibility of measuring aortic stiffness using ultrasound scans of the abdominal aorta coupled with the Bramwell-Hill equation. Healthy subjects were investigated; measurements of cf-PWV were taken by arterial tonometry and aortic systo-diastolic pressure difference was estimated using a validated model. Pulsatility of an abdominal tract of aorta was assessed by automated processing of ultrasound scans. Through a Bland-Altmann analysis, we found large biases when estimating each parameter by applying the Bramwell-Hill equation to the measured values of the other two paramters (bias, +/- 1.96 SD; PWV, about 2.1 +/- 2.5 m/s; pulsatility, 12 +/- 14%; pressure jump, 47 +/- 55 mmHg). These results indicate that the two measures are not interchangeable, and that a large part of the bias is attributable to blood pressure estimation. Further studies are needed to identify the possible sources of bias between cf-PWV and aortic pulsatility.
File in questo prodotto:
File Dimensione Formato  
bioengineering-09-00265-v2.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 1.04 MB
Formato Adobe PDF
1.04 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/3038042
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact