Objectives: To evaluate the capability of digital tomosynthesis (DTS) to characterize suspected pulmonary lesions in the so-called hidden areas at chest X-ray (CXR). Materials and Methods: Among 726 patients with suspected pulmonary lesions at CXR who underwent DTS, 353 patients (201 males, 152 females; age 71.5   10.4 years) revealed suspected pulmonary lesions in the apical, hilar, retrocardiac, or paradiaphragmatic lung zones and were retrospectively included. Two readers analyzed CXR and DTS images and provided a confidence score: 1 or 2 = definitely or probably benign pulmonary or extra-pulmonary lesion, or pulmonary pseudo-lesion deserving no further diagnostic work-up; 3 = indeterminate lesion; 4 or 5 = probably or definitely pulmonary lesion deserving further diagnostic work-up by CT. The nature of DTS findings was proven by CT (n = 108) or CXR during follow-up (n = 245). Results: In 62/353 patients the suspected lung lesions were located in the lung apex, in 92/353 in the hilar region, in 59/353 in the retrocardiac region, and in 140/353 in the paradiaphragmatic region. DTS correctly characterized the CXR findings as benign pulmonary or extrapulmonary lesion (score 1 or 2) in 43/62 patients (69%) in the lung apex region, in 56/92 (61%) in the pulmonary hilar region, in 40/59 (67%) in the retrocardiac region, and in 106/140 (76%) in the paradiaphragmatic region, while correctly recommending CT in the remaining cases due to the presence of true solid pulmonary lesion, with the exception of 22 false negative findings (60 false positive findings). DTS showed a significantly (p < 0.05) increased sensitivity, specificity, and overall diagnostic accuracy and area under ROC curve compared to CXR alone. Conclusions: DTS allowed confirmation or exclusion of the presence of true pulmonary lesions in the hidden areas of the chest.

Digital Tomosynthesis as a Problem-Solving Technique to Confirm or Exclude Pulmonary Lesions in Hidden Areas of the Chest

Baratella, Elisa
;
Minelli, Pierluca;Ruaro, Barbara;Cova, Maria Assunta
2023-01-01

Abstract

Objectives: To evaluate the capability of digital tomosynthesis (DTS) to characterize suspected pulmonary lesions in the so-called hidden areas at chest X-ray (CXR). Materials and Methods: Among 726 patients with suspected pulmonary lesions at CXR who underwent DTS, 353 patients (201 males, 152 females; age 71.5   10.4 years) revealed suspected pulmonary lesions in the apical, hilar, retrocardiac, or paradiaphragmatic lung zones and were retrospectively included. Two readers analyzed CXR and DTS images and provided a confidence score: 1 or 2 = definitely or probably benign pulmonary or extra-pulmonary lesion, or pulmonary pseudo-lesion deserving no further diagnostic work-up; 3 = indeterminate lesion; 4 or 5 = probably or definitely pulmonary lesion deserving further diagnostic work-up by CT. The nature of DTS findings was proven by CT (n = 108) or CXR during follow-up (n = 245). Results: In 62/353 patients the suspected lung lesions were located in the lung apex, in 92/353 in the hilar region, in 59/353 in the retrocardiac region, and in 140/353 in the paradiaphragmatic region. DTS correctly characterized the CXR findings as benign pulmonary or extrapulmonary lesion (score 1 or 2) in 43/62 patients (69%) in the lung apex region, in 56/92 (61%) in the pulmonary hilar region, in 40/59 (67%) in the retrocardiac region, and in 106/140 (76%) in the paradiaphragmatic region, while correctly recommending CT in the remaining cases due to the presence of true solid pulmonary lesion, with the exception of 22 false negative findings (60 false positive findings). DTS showed a significantly (p < 0.05) increased sensitivity, specificity, and overall diagnostic accuracy and area under ROC curve compared to CXR alone. Conclusions: DTS allowed confirmation or exclusion of the presence of true pulmonary lesions in the hidden areas of the chest.
2023
Pubblicato
https://www.mdpi.com/2075-4418/13/6/1010
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10046899/
File in questo prodotto:
File Dimensione Formato  
diagnostics-13-01010.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 961.34 kB
Formato Adobe PDF
961.34 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/3041258
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact