The shear modulus G of the sputum obtained by expectoration from cystic fibrosis patients is fundamental to determine the mesh size of the polymeric network pervading the sputum, a parameter related to lung functionality. The Akaike criterion revealed that in 55.2 % of the examined samples, the best approach (among those considered) to de-termine G relied on the mechanical spectrum fitting by the generalised Maxwell model with relaxation times scaled by a factor 10. Thus, this approach was adopted to evaluate the mesh size distribution combining G knowledge with the determination of the average magnetic relaxation time (T2m) of sputum. As G and T2m determination can be negatively affected by sputum contamination by saliva, whose presence increases T2m and depresses G, we developed a proper "decontamination" procedure to obtain more reliable T2m and G estimations (necessary in 21 % of the samples). This procedure allowed to strengthen the T2m correlation with lung functionality evaluated by FEV1 (normalised air volume emitted in the first second during a spirometry test).

Rheological and Low Field NMR Characterisation of Cystic Fibrosis Patient's Sputum

Biasin, A;Gerin, F;Confalonieri, M;Grassi, G;Grassi, M;Abrami, M
2022-01-01

Abstract

The shear modulus G of the sputum obtained by expectoration from cystic fibrosis patients is fundamental to determine the mesh size of the polymeric network pervading the sputum, a parameter related to lung functionality. The Akaike criterion revealed that in 55.2 % of the examined samples, the best approach (among those considered) to de-termine G relied on the mechanical spectrum fitting by the generalised Maxwell model with relaxation times scaled by a factor 10. Thus, this approach was adopted to evaluate the mesh size distribution combining G knowledge with the determination of the average magnetic relaxation time (T2m) of sputum. As G and T2m determination can be negatively affected by sputum contamination by saliva, whose presence increases T2m and depresses G, we developed a proper "decontamination" procedure to obtain more reliable T2m and G estimations (necessary in 21 % of the samples). This procedure allowed to strengthen the T2m correlation with lung functionality evaluated by FEV1 (normalised air volume emitted in the first second during a spirometry test).
File in questo prodotto:
File Dimensione Formato  
CABEQ 2022 36(4) 239-253.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 1.43 MB
Formato Adobe PDF
1.43 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/3046198
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact