Innovative, low-loss, and compact optical systems are essential to meet the experimental requirements of emerging novel radiation sources. The microchannel plate (MCP), a metamaterial-based optical device, shows promising potential for shaping, condensing, and focusing soft x-ray radiation at synchrotron radiation (SR) facilities. This study highlights the impact of MCP optical devices on SR beam condensing capability and their sensitivity to the degree of coherence by investigating the profile of transmitted beams through single and double MCP optical devices. Transmitted diffraction patterns of soft x-ray SR radiation change with energy and radiation modes. At 92 eV, the double MCP-based device affects the beam divergence and degree of coherence more than the single MCP. Moreover, the double MCP device shows potential as a condensing optics at shorter wavelengths, i.e., 480 eV. Experiments were performed at the available end-station of the Circular Polarization beamline at the Elettra synchrotron facility in Trieste, using a high-vacuum chamber with a hexapod system, providing the precise movement necessary to align these diffractive optics. The findings contribute to the development of innovative optical systems for SR and free-electron laser beamlines, paving the way for advanced experiments in spectroscopy, microscopy, and imaging in a wide energy range.

Characterization in the extreme ultraviolet (XUV) domain of microchannel plate based device using synchrotron radiation

Cautero, Marco;
2023-01-01

Abstract

Innovative, low-loss, and compact optical systems are essential to meet the experimental requirements of emerging novel radiation sources. The microchannel plate (MCP), a metamaterial-based optical device, shows promising potential for shaping, condensing, and focusing soft x-ray radiation at synchrotron radiation (SR) facilities. This study highlights the impact of MCP optical devices on SR beam condensing capability and their sensitivity to the degree of coherence by investigating the profile of transmitted beams through single and double MCP optical devices. Transmitted diffraction patterns of soft x-ray SR radiation change with energy and radiation modes. At 92 eV, the double MCP-based device affects the beam divergence and degree of coherence more than the single MCP. Moreover, the double MCP device shows potential as a condensing optics at shorter wavelengths, i.e., 480 eV. Experiments were performed at the available end-station of the Circular Polarization beamline at the Elettra synchrotron facility in Trieste, using a high-vacuum chamber with a hexapod system, providing the precise movement necessary to align these diffractive optics. The findings contribute to the development of innovative optical systems for SR and free-electron laser beamlines, paving the way for advanced experiments in spectroscopy, microscopy, and imaging in a wide energy range.
File in questo prodotto:
File Dimensione Formato  
063102_1_5.0161701.pdf

embargo fino al 10/08/2024

Tipologia: Documento in Versione Editoriale
Licenza: Copyright Editore
Dimensione 2.63 MB
Formato Adobe PDF
2.63 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
063102_1_5.0161701-Post_print.pdf

accesso aperto

Tipologia: Bozza finale post-referaggio (post-print)
Licenza: Digital Rights Management non definito
Dimensione 2.76 MB
Formato Adobe PDF
2.76 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/3054740
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact