We report the design, fabrication, and testing of a humidity sensor based on an optical fiber-based evanescent wave probe. The fiber was bent into a U-shape and de-cladded at the location of the bending. The de-cladded section was coated either with Au or with ZnO nanoparticles. Humidity is detected based on the interaction in the surface plasmon resonance of the Au/ZnO nanoparticles excited by an evanescent wave of light passing through the optical fiber. The response of the U-bent fibers to humidity was investigated using a specifically designed low-voltage portable interrogation box. We found that the fibers coated with ZnO nanoparticles were able to detect a minimum 0.1% change in humidity with an average sensitivity of 143 µV/%RH and 95% linearity over the 10% to 80% humidity range. In comparison, samples coated with Au and Au + ZnO nanoparticles demonstrated a minimum change detection of 0.3% RH and 2% RH respectively. The response and recovery time of the sensor were measured to be 3 s and 4 s, respectively, for a 60% change in humidity from 20% to 80%. The entire measurement system was operated by consuming an electrical power of 1.62 W at an input voltage of 12 Vdc.
Evanescent-Field Excited Surface Plasmon-Enhanced U-Bent Fiber Probes Coated with Au and ZnO Nanoparticles for Humidity Detection
Rosei F.;
2023-01-01
Abstract
We report the design, fabrication, and testing of a humidity sensor based on an optical fiber-based evanescent wave probe. The fiber was bent into a U-shape and de-cladded at the location of the bending. The de-cladded section was coated either with Au or with ZnO nanoparticles. Humidity is detected based on the interaction in the surface plasmon resonance of the Au/ZnO nanoparticles excited by an evanescent wave of light passing through the optical fiber. The response of the U-bent fibers to humidity was investigated using a specifically designed low-voltage portable interrogation box. We found that the fibers coated with ZnO nanoparticles were able to detect a minimum 0.1% change in humidity with an average sensitivity of 143 µV/%RH and 95% linearity over the 10% to 80% humidity range. In comparison, samples coated with Au and Au + ZnO nanoparticles demonstrated a minimum change detection of 0.3% RH and 2% RH respectively. The response and recovery time of the sensor were measured to be 3 s and 4 s, respectively, for a 60% change in humidity from 20% to 80%. The entire measurement system was operated by consuming an electrical power of 1.62 W at an input voltage of 12 Vdc.File | Dimensione | Formato | |
---|---|---|---|
processes-11-00642.pdf
accesso aperto
Tipologia:
Documento in Versione Editoriale
Licenza:
Creative commons
Dimensione
4.96 MB
Formato
Adobe PDF
|
4.96 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.